Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2019 Oct;33(5):815-824.
doi: 10.1007/s10877-018-0235-z. Epub 2018 Dec 15.

Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study

Affiliations
Observational Study

Photoplethysmographic characterization of vascular tone mediated changes in arterial pressure: an observational study

Gerardo Tusman et al. J Clin Monit Comput. 2019 Oct.

Abstract

To determine whether a classification based on the contour of the photoplethysmography signal (PPGc) can detect changes in systolic arterial blood pressure (SAP) and vascular tone. Episodes of normotension (SAP 90-140 mmHg), hypertension (SAP > 140 mmHg) and hypotension (SAP < 90 mmHg) were analyzed in 15 cardiac surgery patients. SAP and two surrogates of the vascular tone, systemic vascular resistance (SVR) and vascular compliance (Cvasc = stroke volume/pulse pressure) were compared with PPGc. Changes in PPG amplitude (foot-to-peak distance) and dicrotic notch position were used to define 6 classes taking class III as a normal vascular tone with a notch placed between 20 and 50% of the PPG amplitude. Class I-to-II represented vasoconstriction with notch placed > 50% in a small PPG, while class IV-to-VI described vasodilation with a notch placed < 20% in a tall PPG wave. 190 datasets were analyzed including 61 episodes of hypertension [SAP = 159 (151-170) mmHg (median 1st-3rd quartiles)], 84 of normotension, SAP = 124 (113-131) mmHg and 45 of hypotension SAP = 85(80-87) mmHg. SAP were well correlated with SVR (r = 0.78, p < 0.0001) and Cvasc (r = 0.84, p < 0.0001). The PPG-based classification correlated well with SAP (r = - 0.90, p < 0.0001), SVR (r = - 0.72, p < 0.0001) and Cvasc (r = 0.82, p < 0.0001). The PPGc misclassified 7 out of the 190 episodes, presenting good accuracy (98.4% and 97.8%), sensitivity (100% and 94.9%) and specificity (97.9% and 99.2%) for detecting episodes of hypotension and hypertension, respectively. Changes in arterial pressure and vascular tone were closely related to the proposed classification based on PPG waveform.Clinical Trial Registration NTC02854852.

Keywords: Arterial pressure; Photoplethysmography; Vascular tone; Vasoconstriction; Vasodilation.

PubMed Disclaimer

References

    1. Med Biol Eng Comput. 1998 Nov;36(6):748-53 - PubMed
    1. Am J Hypertens. 2000 Feb;13(2):165-71 - PubMed
    1. Intensive Care Med. 2000 Feb;26(2):180-7 - PubMed
    1. Anesthesiology. 2000 Jul;93(1):48-54 - PubMed
    1. Circ Res. 1975 May;36(5):565-70 - PubMed

Publication types

MeSH terms

LinkOut - more resources