Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 May;24(3):474-481.
doi: 10.1016/j.jos.2018.11.008. Epub 2018 Dec 13.

The optimal combined anteversion pattern to achieve a favorable impingement-free angle in total hip arthroplasty

Affiliations

The optimal combined anteversion pattern to achieve a favorable impingement-free angle in total hip arthroplasty

Takaaki Ohmori et al. J Orthop Sci. 2019 May.

Abstract

Background: There have been no studies on the differences in impingement-free angle that result from different combined anteversion (CA) patterns. The aim of this study was to find the optimal CA pattern for achieving a favorable impingement-free angle, including bony and prosthetic impingement, in total hip arthroplasty.

Methods: We evaluated 100 patients with no hip arthritis. We investigated the impingement-free angle (flexion, internal rotation with 90° flexion, extension, and external rotation) after changing the stem and cup anteversions to satisfy several CA patterns [cup anteversion + stem anteversion = 30°, 40°, 50°, and 60°; cup anteversion + 0.7 × stem anteversion = 37.3° (:Widmer's theory); and cup anteversion + 0.77 × stem anteversion = 43.3° (:Yoshimine's theory)] using 3-dimensional templating software.

Results: The impingement-free angle changed dramatically among the various CA patterns. The optimal CA was changed by various stem anteversion. Only CA: Widmer with stem anteversion of 20° satisfied daily-life range of motion (ROM) requirements (flexion ≥130°, internal rotation with 90° flexion ≥ 45°, extension ≥ 40°, external rotation ≥ 40°).

Conclusion: Good impingement-free angle cannot be obtained with single fixed CA. Different CA patterns should be used, depending on the differences in the stem anteversion. A CA of 30° with 0° ≤ stem anteversion ≤10°; a CA:Widmer with 20° of stem anteversion; a CA of 40° or Widmer with 30° of stem anteversion. When stem anteversion is ≥40°, CA should be decided by each patient's state. Among them, a stem anteversion of 20° with cup anteversion of 23.3° was found to be the best CA pattern.

PubMed Disclaimer

MeSH terms

LinkOut - more resources