. 2018 Sep 27;34(6):632-639.
doi: 10.1002/joa3.12123. eCollection 2018 Dec.

Cardiac implantable electronic device infection in the cardiac referral center in Thailand: incidence, microbiology, risk factors, and outcomes

Affiliations

Cardiac implantable electronic device infection in the cardiac referral center in Thailand: incidence, microbiology, risk factors, and outcomes

Theerawat Korkerdsup et al. J Arrhythm. .

Abstract

Background: Despite the long experience of cardiac implantable electronic device (CIED) implantation in Thailand, epidemiology of CIED infection in Thailand has never been studied.

Methods: A retrospective cohort study was conducted at the cardiac referral center in Thailand to investigate incidence of CIED infection and causative organisms between October 2002 and December 2017. A matched case-control study was performed to determine the factors associated with CIED infection.

Results: Incidence of CIED infection was 0.9% with a stable trend during the studied period. There were 54 episodes of CIED infection. The median (interquartile range) age of the patients was 67.5 (53.0-75.0) years. A total of 29 (53.7%), 18 (33.3%), and 7 (13.0%) were permanent pacemaker, automatic implantable cardioverter-defibrillator, and cardio-resynchronization therapy-related infection, respectively. Gram-positive cocci were the most common organism (24 episodes, 44.4%). Gram-negative bacilli were isolated in six episodes (11.1%). About 9.3% were polymicrobial and 35.2% were culture negative. Multivariate analysis showed that previous CIED infection and generator revision procedure were associated with CIED infection (odds ratio [OR] 48.56, 95% confidence interval [CI] 3.72-633.62; P = 0.003 and OR 19.99, 95% CI 1.28-333.24; P = 0.033 respectively). Forty (74.1%) cases were cured. Leaving device in situ was the only factor significantly associated with poor outcome (OR 11.40, 95% CI 1.52-85.73; P = 0.018).

Conclusions: In Thailand, while CIED implantation is rising, incidence of CIED infection is stable. Microbiology of CIED infection in Thailand is similar to western countries, albeit a higher proportion of negative culture. Previous CIED infection and generator revision procedure are associated with CIED infection.

Keywords: Thailand; cardiac implantable electronic device infection; microbiology; risk factors; treatment outcome.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Annual number of CIED implantation in Ramathibodi Hospital
Figure 2
Figure 2
Incidence of CIED infection comparing to annual number of CIED implantation
Figure 3
Figure 3
Microbiology of CIED infection (n = 54). CoNS, coagulase‐negative Staphylococcus; MRSA, methicillin‐resistant Staphylococcus aureus; MSSA, methicillin‐susceptible Staphylococcus aureus

References

    1. Mond HG, Proclemer A. The 11th world survey of cardiac pacing and implantable cardioverter‐defibrillators: calendar year 2009–a World Society of Arrhythmia's project. Pacing Clin Electrophysiol. 2011;34:1013–1027. - PubMed
    1. Greenspon AJ, Patel JD, Lau E, et al. 16‐year trends in the infection burden for pacemakers and implantable cardioverter‐defibrillators in the United States 1993 to 2008. J Am Coll Cardiol. 2011;58:1001–1006. - PubMed
    1. Sandoe JA, Barlow G, Chambers JB, et al. Guidelines for the diagnosis, prevention and management of implantable cardiac electronic device infection. Report of a joint Working Party project on behalf of the British Society for Antimicrobial Chemotherapy (BSAC, host organization), British Heart Rhythm Society (BHRS), British Cardiovascular Society (BCS), British Heart Valve Society (BHVS) and British Society for Echocardiography (BSE). J Antimicrob Chemother. 2015;70:325–359. - PubMed
    1. Cunningham D, Charles R, Cunningham M, de Lange A. Cardiac rhythm management: UK national clinical audit 2010. Partnership HQI, editor, 2011.
    1. Klug D, Balde M, Pavin D, et al. Risk factors related to infections of implanted pacemakers and cardioverter‐defibrillators: results of a large prospective study. Circulation. 2007;116:1349–1355. - PubMed