Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Apr;38(4):396-405.
doi: 10.1016/j.healun.2018.11.003. Epub 2018 Nov 15.

Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device

Affiliations

Prognostic implications of serial outpatient blood pressure measurements in patients with an axial continuous-flow left ventricular assist device

Alberto Pinsino et al. J Heart Lung Transplant. 2019 Apr.

Abstract

Background: Elevated blood pressure (BP) has been linked to adverse events during left ventricular assist device support. In this study we investigated the association between outpatient BP and stroke or suspected pump thrombosis among HeartMate II (HMII) recipients.

Methods: We retrospectively studied 220 HMII patients. Serial outpatient BP measurements were averaged. Patients were categorized by: (1) mean arterial pressure (MAP), high (>90 mm Hg) vs intermediate (80 mm Hg ≤ MAP ≤ 90 mm Hg) vs low (<80 mm Hg); (2) systolic BP (SBP), high (≥101 mm Hg, median) vs low; and (3) pulse pressure (PP), high (≥22 mm Hg, median) vs low. To assess visit-to-visit BP variability, patients were divided in quartiles of standard deviation of MAP and SBP. The primary end-point was the composite of stroke or suspected pump thrombosis.

Results: The risk for the primary end-point was increased in the high MAP group (adjusted hazard ratio [HR] 2.75, 95% confidence interval [CI] 1.49 to 5.05, vs intermediate MAP; and 6.73, 1.9 to 23.9, vs low MAP). MAP had higher predictive value for the primary end-point compared with SBP (p = 0.05). Patients with high SBP had a higher rate of stroke (HR 2.8, 95% CI 1.09 to 7.17, vs low SBP). The combination of high SBP and low PP was associated with the highest risk for stroke. The lowest quartile of visit-to-visit MAP variability was associated with the highest risk for the primary end-point.

Conclusions: Elevated outpatient BP is associated with increased risk for stroke or suspected pump thrombosis in HMII recipients. Reduced PP and low visit-to-visit BP variability may confer additional risk.

Keywords: Blood Pressure; LVAD; MCS; Pulsatility; Pump Thrombosis; Stroke.