. 2019 Jan 16;11(2):2317-2327.
doi: 10.1021/acsami.8b19425. Epub 2019 Jan 7.

A Stretchable Strain-Insensitive Temperature Sensor Based on Free-Standing Elastomeric Composite Fibers for On-Body Monitoring of Skin Temperature

Affiliations

A Stretchable Strain-Insensitive Temperature Sensor Based on Free-Standing Elastomeric Composite Fibers for On-Body Monitoring of Skin Temperature

Tran Quang Trung et al. ACS Appl Mater Interfaces. .

Abstract

To realize the potential applications of stretchable sensors in the field of wearable health monitoring, it is essential to develop a stable sensing device with robust electrical and mechanical properties in the present of varying external conditions. Herein, we demonstrate a stretchable temperature sensor with the elimination of strain-induced interference via geometric engineering of the free-standing stretchable fibers (FSSFs) of reduced graphene oxide/polyurethane composite. The FSSFs were formed in serpentine structures and enabled the implementation of a strain-insensitive stretchable temperature sensor. On the basis of the controlled reduction time of graphene oxide, we can modulate the response and thermal index of the device. These results are attributed to the variation in the density of oxygen-containing functional groups in the FSSFs, which affect the hopping charge transport and thermal generation of excess carriers. The FSSF temperature sensor yields increased responsivity (0.8%/°C), stretchability (90%), sensing resolution (0.1 °C), and stability in response to applied stretching (±0.37 °C for strains ranging from 0 to 50%). When the sensor is sewn onto a stretchable bandage and attached to the human body, it can detect the temperature changes of the human skin during different body motions in a continuous and stable manner.

Keywords: elastomeric composite fiber; reduced graphene oxide; skin temperature monitoring; strain-insensitive sensor; stretchable temperature sensor.