Diagnostic value of computed tomography for detecting anastomotic or staple line leakage after bariatric surgery
- PMID: 30580770
- DOI: 10.1016/j.soard.2018.05.007
Diagnostic value of computed tomography for detecting anastomotic or staple line leakage after bariatric surgery
Abstract
Background: Postbariatric anastomotic or staple line leakage (ASLL) is a dreaded complication with an incidence up to 1.6% and a leak-associated mortality of 5.0% to 16.7%. Feared low sensitivity of abdominal computed tomography (CT) for detecting ASLL is causing surgeons to omit CT and directly perform a diagnostic laparoscopy in patients with suspected ASLL.
Objectives: To evaluate the diagnostic value of CT in case of suspected ASLL after bariatric procedures and to identify reliable CT characteristics predicting the presence of ASLL.
Setting: A large teaching hospital and bariatric center of excellence.
Methods: All CT scans performed for suspected ASLL after bariatric surgery in the period November 2007 until August 2016 were independently reevaluated by abdominal radiologists. The diagnostic value of CT by means of sensitivity, specificity, and positive and negative predictive value was analyzed comparing results of reevaluation to a standard of reference. Multivariable regression was performed to identify reliable CT characteristics for the presence of ASLL.
Results: A total of 66 CT scans were performed because of suspected leakage. Reevaluation of CT scans revealed a sensitivity of 89% to 100%, a specificity of 69% to 78%, a positive predictive value of 39% to 50%, and a negative predictive value of 97% to 100% of CT for detecting ASLL after bariatric surgery. Multivariable logistic regression of ASLL characteristics on CT revealed 'air near the anastomosis/staple line' as the only independent predictor for the presence of ASLL.
Conclusion: With a sensitivity of 89% to 100% and negative predictive value of 97% to 100%, a negative CT can rule out ASLL in patients with a lower suspicion of ASLL.
Keywords: Anastomotic leakage; Bariatric surgery; Computed tomography; Diagnostic laparoscopy; Staple line leakage.
Copyright © 2018 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.
Comment in
-
Comment on: diagnostic value of computed tomography for detecting anastomotic or staple line leakage after bariatric surgery.Surg Obes Relat Dis. 2018 Sep;14(9):1318. doi: 10.1016/j.soard.2018.06.001. Epub 2018 Jun 14. Surg Obes Relat Dis. 2018. PMID: 30005864 No abstract available.
-
Comment on: diagnostic value of computed tomography for detecting anastomotic or staple line leakage after bariatric surgery.Surg Obes Relat Dis. 2018 Sep;14(9):1317. doi: 10.1016/j.soard.2018.07.006. Epub 2018 Aug 8. Surg Obes Relat Dis. 2018. PMID: 30205941 No abstract available.
MeSH terms