Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Review
. 1988 Sep;2(3):1613-29.

Quantitative analysis of particulate burden in lung tissue

Affiliations
  • PMID: 3059480
Review

Quantitative analysis of particulate burden in lung tissue

J P Mastin et al. Scanning Microsc. 1988 Sep.

Abstract

Numerous methods have been used in the preparation and analysis of the particulate matter deposited in human lungs. Preparation techniques include those for particle isolation and for in situ analysis. Analytical techniques include bulk and particle-by-particle analysis. In this paper, a general discussion of many of these methods is presented along with examples of how two specific techniques have been used. In one study, individual particles from the lungs of 75 randomly selected autopsy cases were analyzed using an automated scanning electron microscopy (SEM)/energy dispersive X-ray microanalysis (EDX) system. An average of 613 million particles, of exogenous origin, per gram of dry lung tissue were found, the major classes of particles being silica, talc, aluminum silicates, and rutile. In the second study, lungs from 50 randomly selected autopsy cases were analyzed using gravimetric and X-ray diffraction (XRD) analysis. The median total particulate material was 0.33 grams, for cases in which samples were prepared by high temperature ashing, and 0.41 grams, for those in which nitric acid digestion was used. The median amount of quartz for all cases, was 0.044 grams. Samples of eighteen of the 75 lungs previously analyzed by automated SEM/EDX were also analyzed using gravimetric and XRD analysis. A good correlation was seen between the results of the two procedures (r = 0.91 for number of exogenous particles versus grams of particulate matter and r = 0.97 for number of silica particles versus amount of quartz).

PubMed Disclaimer

Similar articles

Cited by

  • Pathology and Mineralogy of the Pneumoconioses.
    Hua JT, Cool CD, Green FHY. Hua JT, et al. Semin Respir Crit Care Med. 2023 Jun;44(3):327-339. doi: 10.1055/s-0043-1764406. Epub 2023 Mar 27. Semin Respir Crit Care Med. 2023. PMID: 36972614 Free PMC article. Review.