Observational Study
. 2019 Jan 2;14(1):e0206611.
doi: 10.1371/journal.pone.0206611. eCollection 2019.

Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

Affiliations
Observational Study

Cardiac implantable electronic device (CIED) infections are expensive and associated with prolonged hospitalisation: UK Retrospective Observational Study

Fozia Zahir Ahmed et al. PLoS One. .

Erratum in

Abstract

Background: There are limited reports outlining the financial cost of treating cardiac implantable electronic device (CIED) infection outside the United States. This study aimed to determine the average treatment cost of CIED infection in a large UK tertiary referral centre and compared costs of different treatment pathways that are recognised in the management of CIED infection (early versus delayed re-implantation).

Methods: We retrospectively analysed cost and length of stay (LOS) data for consecutive patients undergoing infected CIED extraction with cardiac resynchronization therapy (CRT-D [with defibrillator], CRT-P [with pacemaker]), implantable cardioverter-defibrillators (ICDs) and permanent pacemakers (PPMs).

Results: Between January 2013 and March 2015, complete data was available for 84 patients (18 [21.4%] CRT-D, 24 [28.6%] ICDs and 42 [50.0%] PPMs). When all cases were considered the cost of infection ranged from £5,139 (PPM) to £24,318 (CRT-D). Considering different treatment strategies; 41 (48.8%) underwent CIED extraction and re-implantation during the same admission (early re-implant strategy (ER). 43 (51.2%) underwent extraction, but were then discharged home to be re-admitted for day-case re-implantation (delayed re-implant strategy (DR)). Median LOS was significantly shorter in DR compared to ER (5.0 vs. 18.0 days, p<0.001). The total cost of CIED infection episode was similar for both treatment strategies (median £14,241.48 vs. £14,741.70 including wearable defibrillator (Lifevest) and outpatient antibiotics costs, ER vs. DR; p = 0.491).

Conclusion: CIED infections are expensive and associated with significant health-economic burden. When all device types were considered, a DR strategy is associated with reduced LOS without an increased cost penalty.

PubMed Disclaimer

Conflict of interest statement

FZA has previously received a research grant (unrelated to this study) funded by Medtronic. There are no patents, products in development or marketed products to declare. This does not alter our adherence to all the PLOS ONE policies on sharing data and materials.

References

    1. Greenspon AJ, Patel JD, Lau E, Ochoa JA, Frisch DR, Ho RT, et al. 16-year trends in the infection burden for pacemakers and implantable cardioverter-defibrillators in the United States 1993 to 2008. J Am Coll Cardiol. 2011;58(10):1001–6. 10.1016/j.jacc.2011.04.033 - DOI - PubMed
    1. Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. 2005;352(15):1539–49. 10.1056/NEJMoa050496 - DOI - PubMed
    1. Moss AJ, Hall WJ, Cannom DS, Daubert JP, Higgins SL, Klein H, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter Automatic Defibrillator Implantation Trial Investigators. N Engl J Med. 1996;335(26):1933–40. 10.1056/NEJM199612263352601 - DOI - PubMed
    1. Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83. 10.1056/NEJMoa013474 - DOI - PubMed
    1. Voigt A, Shalaby A, Saba S. Rising rates of cardiac rhythm management device infections in the United States: 1996 through 2003. J Am Coll Cardiol. 48 United States2006. p. 590–1. 10.1016/j.jacc.2006.05.016 - DOI - PubMed