Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2019 Jul;11(7):683-689.
doi: 10.1136/neurintsurg-2018-014517. Epub 2019 Jan 4.

Stent-assisted coiling of cerebral aneurysms using the Y-stenting technique: a systematic review and meta-analysis

Affiliations
Meta-Analysis

Stent-assisted coiling of cerebral aneurysms using the Y-stenting technique: a systematic review and meta-analysis

Manuel F Granja et al. J Neurointerv Surg. 2019 Jul.

Abstract

Background: Bifurcation aneurysms can be treated with stent-assisted coiling using two stents in a Y-configuration. We aim to investigate the angiographic and clinical outcomes of Y-stent constructs for the treatment of intracranial aneurysms.

Methods: A systematic review of PubMed, Ovid MEDLINE, and Ovid EMBASE databases was conducted based on PRISMA guidelines. The study selection was performed using the 'Ryyan' application. Our analysis included 18 studies with 327 patients. Inclusion criteria were: articles published from January 2000 to November 2017, English language, including cerebral aneurysms treated via Y-stenting, and ≥5 cases with radiographic/clinical outcomes. Technical notes, editorials, reviews, and animal studies were excluded. A random-effect meta-analysis was performed on angiographic and clinical outcomes, including aneurysm occlusion, modified Rankin Scale, neurological outcome, and procedure-related mortality. 95% CIs and event rates were estimated. Statistical heterogeneity was assessed using I2 statistics.

Results: The procedure-related good outcome rate was 92% and complete occlusion rate was 91%. The permanent neurological deficit rate was 4% and procedure-related mortality was 2%. The procedure-related stroke rate was 12%. A total of 28/146 (19%) patients had ruptured aneurysms. At long-term follow-up, overall stroke rate was 9% in patients with unruptured aneurysm. The mortality rate was higher in cases with ruptured aneurysms than in those with unruptured aneurysms (18% vs 0.8%; p<0.001).

Conclusions: Y-stenting for bifurcation aneurysms yields a high rate of complete occlusion and low rates of mortality and stroke. Careful patient selection is needed.

Keywords: intervention; intracranial aneurysm; stent.

PubMed Disclaimer

Conflict of interest statement

Competing interests: RAH is a consultant for Medtronic, Stryker, Codman, and MicroVention.

MeSH terms

LinkOut - more resources