Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2019 Apr;174(3):669-677.
doi: 10.1007/s10549-018-05122-7. Epub 2019 Jan 5.

Three-dimensional tumor visualization of invasive breast carcinomas using whole-mount serial section histopathology: implications for tumor size assessment

Affiliations
Comparative Study

Three-dimensional tumor visualization of invasive breast carcinomas using whole-mount serial section histopathology: implications for tumor size assessment

G M Clarke et al. Breast Cancer Res Treat. 2019 Apr.

Abstract

Purpose: Linear tumor size (T-size) estimated with conventional histology informs breast cancer management. Previously we demonstrated significant differences in margin and focality estimates using conventional histology versus digital whole-mount serial sections (WMSS). Using WMSS we can measure T-size or volume. Here, we compare WMSS T-size with volume, and with T-size measured conventionally. We also compare the ellipsoid model for calculating tumor volume to direct, WMSS measurement.

Methods: Two pathologists contoured regions of invasive carcinoma and measured T-size from both WMSS and (simulated) conventional sections in 55 consecutive lumpectomy specimens. Volume was measured directly from the contours. Measurements were compared using the paired t-test or Spearman's rank-order correlation. A five-point 'border index' was devised and assigned to each case to parametrize tumor shape considering 'compactness' or cellularity. Tumor volumes calculated assuming ellipsoid geometry were compared with direct, WMSS measurements.

Results: WMSS reported significantly larger T-size than conventional histology in the majority of cases [61.8%, 34/55; means = (2.34 cm; 1.99 cm), p < 0.001], with a 16.4% (9/55) rate of 'upstaging'. The majority of discordances were due to undersampling. T-size and volume were strongly correlated (r = 0.838, p < 0.001). Significantly lower volume was obtained with WMSS versus ellipsoid modeling [means = (1.18 cm3; 1.45 cm3), p < 0.001].

Conclusions: Significantly larger T-size is measured with WMSS than conventionally, due primarily to undersampling in the latter. Volume and linear size are highly correlated. Diffuse tumors interspersed with normal or non-invasive elements may be sampled less extensively than more localized masses. The ellipsoid model overestimates tumor volume.

Keywords: Breast cancer; Histologic size; Large-format histology; Lumpectomy; Tumor volume; Whole-mount serial sections.

PubMed Disclaimer

Publication types

LinkOut - more resources