The premature infant's respiratory response to mechanical ventilation
- PMID: 3061770
- DOI: 10.1016/s0378-3782(88)80051-3
The premature infant's respiratory response to mechanical ventilation
Abstract
Comparisons of the components of ventilator waveform were made in two groups of preterm infants ventilated for the respiratory distress syndrome. Infants actively expiring against positive pressure inflation were compared to infants not showing this interaction. The actively expiring infants were ventilated with a higher peak inspiratory pressure (P less than 0.01) and a significantly greater duration of positive pressure plateau (P less than 0.05) than the control group. The two groups were well matched for gestational and postnatal age and there were no other significant differences in the components of ventilator waveform. Adoption of a ventilator waveform with a shorter positive pressure plateau and less steep rise in positive pressure might reduce the incidence of active expiration and hence pneumothoraces.
Similar articles
-
Pancuronium prevents pneumothoraces in ventilated premature babies who actively expire against positive pressure inflation.Lancet. 1984 Jan 7;1(8367):1-3. doi: 10.1016/s0140-6736(84)90177-6. Lancet. 1984. PMID: 6140340 Clinical Trial.
-
Manipulation of ventilator settings to prevent active expiration against positive pressure inflation.Arch Dis Child. 1985 Nov;60(11):1036-40. doi: 10.1136/adc.60.11.1036. Arch Dis Child. 1985. PMID: 3935053 Free PMC article.
-
Inflation time in mechanical ventilation of preterm neonates.Eur J Pediatr. 1991 Apr;150(6):440-3. doi: 10.1007/BF02093728. Eur J Pediatr. 1991. PMID: 2040355
-
Automated respiratory support in newborn infants.Semin Fetal Neonatal Med. 2009 Feb;14(1):35-41. doi: 10.1016/j.siny.2008.08.008. Epub 2008 Oct 1. Semin Fetal Neonatal Med. 2009. PMID: 18829405 Review.
-
Weaning preterm infants from mechanical ventilation.Neonatology. 2008;94(3):197-202. doi: 10.1159/000143722. Epub 2008 Oct 2. Neonatology. 2008. PMID: 18832855 Review.
Cited by
-
Monitoring respiratory activity in neonates using diaphragmatic electromyograph.Med Biol Eng Comput. 1995 May;33(3 Spec No):385-90. doi: 10.1007/BF02510520. Med Biol Eng Comput. 1995. PMID: 7666684
-
High bias gas flows increase lung injury in the ventilated preterm lamb.PLoS One. 2012;7(10):e47044. doi: 10.1371/journal.pone.0047044. Epub 2012 Oct 8. PLoS One. 2012. PMID: 23056572 Free PMC article.
-
Effect of positive end expiratory pressure and mean airway pressure on respiratory compliance and gas exchange in children with liver disease.Eur J Pediatr. 1994 Jan;153(1):28-33. doi: 10.1007/BF02000783. Eur J Pediatr. 1994. PMID: 8313921
-
Randomised controlled trial of two methods of weaning from high frequency positive pressure ventilation.Arch Dis Child. 1989 Jun;64(6):834-8. doi: 10.1136/adc.64.6.834. Arch Dis Child. 1989. PMID: 2505689 Free PMC article. Clinical Trial.
-
Respiratory support using patient triggered ventilation in the neonatal period.Arch Dis Child. 1992 Jan;67(1 Spec No):69-71. doi: 10.1136/adc.67.1_spec_no.69. Arch Dis Child. 1992. PMID: 1536592 Free PMC article. Review.