Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement
- PMID: 30621987
- DOI: 10.1016/j.jcmg.2018.10.020
Imaging for Predicting and Assessing Prosthesis-Patient Mismatch After Aortic Valve Replacement
Abstract
Prosthesis-patient mismatch (PPM) occurs when the effective orifice area (EOA) of the prosthetic valve is too small in relation to a patient's body size, thus resulting in high residual postoperative pressure gradients across the prosthesis. Severe PPM occurs in 2% to 20% of patients undergoing surgical aortic valve replacement (AVR) and is associated with 1.5- to 2.0-fold increase in the risk of mortality and heart failure rehospitalization. The purpose of this article is to present an overview of the role of multimodality imaging in the assessment, prediction, prevention, and management of PPM following AVR. The risk of PPM can be anticipated at the time of AVR by calculating the predicted indexed from the normal reference value of EOA of the selected prosthesis and patient's body surface area. The strategies to prevent PPM at the time of surgical AVR include: 1) implanting a newer generation of prosthetic valve with better hemodynamic; 2) enlarging the aortic root or annulus to accommodate a larger prosthetic valve; or 3) performing TAVR rather than surgical AVR. The identification and quantitation of PPM as well as its distinction versus prosthetic valve stenosis is primarily based on transthoracic echocardiography, but important information may be obtained from other imaging modalities such as transesophageal echocardiography and multidetector computed tomography. PPM is characterized by high transprosthetic velocity and gradients, normal EOA, small indexed EOA, and normal leaflet morphology and mobility. Transesophageal echocardiography and multidetector computed tomography are particularly helpful to assess prosthetic valve leaflet morphology and mobility, which is a cornerstone of the differential diagnosis between PPM and pathologic valve obstruction. Severe symptomatic PPM following AVR with a bioprosthetic valve may be treated by redo surgery or the transcatheter valve-in-valve procedure with fracturing of the surgical valve stent.
Keywords: Doppler echocardiography; aortic valve replacement; bioprosthesis; multidetector computed tomography; prosthesis-patient mismatch.
Copyright © 2019 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Computed Tomography-Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch.Circ Cardiovasc Interv. 2019 Apr;12(4):e007396. doi: 10.1161/CIRCINTERVENTIONS.118.007396. Circ Cardiovasc Interv. 2019. PMID: 30929507
-
Prosthesis-patient mismatch after transcatheter aortic valve replacement: prevalence and medium term prognostic impact.Int J Cardiovasc Imaging. 2019 May;35(5):827-836. doi: 10.1007/s10554-018-01519-z. Epub 2019 Jan 19. Int J Cardiovasc Imaging. 2019. PMID: 30661140
-
Limitations in the Assessment of Prosthesis-Patient Mismatch.Thorac Cardiovasc Surg. 2020 Oct;68(7):550-556. doi: 10.1055/s-0038-1676814. Epub 2019 Jan 4. Thorac Cardiovasc Surg. 2020. PMID: 30609446
-
Impact of Flow on Prosthesis-Patient Mismatch Following Transcatheter and Surgical Aortic Valve Replacement.Circ Cardiovasc Imaging. 2021 Aug;14(8):e012364. doi: 10.1161/CIRCIMAGING.120.012364. Epub 2021 Aug 13. Circ Cardiovasc Imaging. 2021. PMID: 34387097
-
Transcatheter Aortic Valve Replacement: Role of Multimodality Imaging in Common and Complex Clinical Scenarios.JACC Cardiovasc Imaging. 2020 Jan;13(1 Pt 1):124-139. doi: 10.1016/j.jcmg.2018.10.037. Epub 2019 May 15. JACC Cardiovasc Imaging. 2020. PMID: 31103575 Review.
Cited by
-
Self-expanding vs. balloon-expandable transcatheter heart valves in small aortic annuli.Front Cardiovasc Med. 2023 Aug 3;10:1175246. doi: 10.3389/fcvm.2023.1175246. eCollection 2023. Front Cardiovasc Med. 2023. PMID: 37600053 Free PMC article.
-
Prosthesis-patient mismatch in transcatheter and surgical aortic valve replacement.Ann Cardiothorac Surg. 2024 May 31;13(3):211-223. doi: 10.21037/acs-2023-aae-0166. Epub 2024 Apr 28. Ann Cardiothorac Surg. 2024. PMID: 38841078 Free PMC article. Review.
-
Implanted size and structural valve deterioration in the Edwards Magna bioprosthesis.Ann Cardiothorac Surg. 2024 May 31;13(3):275-282. doi: 10.21037/acs-2024-aae-26. Epub 2024 May 22. Ann Cardiothorac Surg. 2024. PMID: 38841084 Free PMC article.
-
Transcatheter Aortic Valve Implantation by Valve Type in Women With Small Annuli: Results From the SMART Randomized Clinical Trial.JAMA Cardiol. 2024 Dec 1;9(12):1106-1114. doi: 10.1001/jamacardio.2024.3241. JAMA Cardiol. 2024. PMID: 39382856 Clinical Trial.
-
Procedural Strategies in Transcatheter Aortic Valve Replacement for Patients With Small Aortic Annulus and Aortic Stenosis.JACC Case Rep. 2025 May 14;30(10):103929. doi: 10.1016/j.jaccas.2025.103929. Epub 2025 Apr 19. JACC Case Rep. 2025. PMID: 40252065 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical