Real-time data-driven motion correction in PET
- PMID: 30627803
- PMCID: PMC6326913
- DOI: 10.1186/s40658-018-0240-9
Real-time data-driven motion correction in PET
Abstract
PET imaging has been, and continues to be, an evolving diagnostic technology. In recent years, the modernizing digital landscape has opened new opportunities for data-driven innovation. One such facet has been data-driven motion correction (DDMC) in PET. As both research and industry propel this technology forward, we can recognize prospects and opportunities for further development. The concept of clinical practicality is supported by DDMC approaches-it is what sets them apart from traditional hardware-driven motion correction strategies that have largely not gained acceptance in routine diagnostic PET; the ease of use of DDMC may help propel acceptance of motion correction solutions in clinical practice. As we reflect on the present field, we should consider that DDMC can be made even more practical, and likely more impactful, if further developed to fit within a real-time acquisition framework. This vision for development is not new, but has been made more feasible with contemporary electronics, and has begun to be revisited in contemporary literature. The opportunities for development lie on a new forefront of innovation where medical physics integrates with engineering, data science, and modern computing capacities. Real-time DDMC is a systems integration challenge, and achieving it will require cooperation between hardware and software developers, and likely academia and industry. While challenges for development do exist, it is likely that we will see real-time DDMC come to fruition in the coming years. This effort may establish groundwork for developing similar innovations in the emerging digital innovation age.
Keywords: Data-driven gating; Data-driven motion correction; Digital innovation; PET; Real-time.
Conflict of interest statement
Ethics approval and consent to participate
Not applicable.
Consent for publication
Not applicable.
Competing interests
AK’s home institution, Memorial Sloan Kettering Cancer Center, holds several patents relating to data-driven gating and motion correction and has no other potential competing interests to declare. CRS and CK declare that they have no competing interests.
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
References
-
- Kesner A, Schleyer P, Buther F, Walter M, Schafers K, Koo P. On transcending the impasse of respiratory motion correction applications in routine clinical imaging - a consideration of a fully automated data driven motion control framework. EJNMMI Physics. 2014;1:8. doi: 10.1186/2197-7364-1-8. - DOI - PMC - PubMed
-
- Kesner AL, Bundschuh RA, Detorie NC, Dahlbom M, Czernin J, Silverman DHS. Respiratory gated PET derived from raw PET data: Nuclear Science Symposium Conference Record, 2007 NSS '07 IEEE; 2007. p. 2686–91.
-
- Kesner AL, Bundschuh RA, Detorie NC, Dahlbom M, Ziegler SI, Czernin J, et al. Respiratory gated PET derived in a fully automated manner from raw PET data. Nuclear Sci IEEE Trans. 2009;56:677–686. doi: 10.1109/TNS.2009.2016341. - DOI
Publication types
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials