Ex Vivo Evaluation of Secretion-Clearing Device in Reducing Airway Resistance within Endotracheal Tubes

Affiliations

Ex Vivo Evaluation of Secretion-Clearing Device in Reducing Airway Resistance within Endotracheal Tubes

Christopher Waters et al. Crit Care Res Pract. .

Abstract

Background: Secretions accumulate in endotracheal tubes' (ETT) lumens upon their placement in patients. The secretions impact airway resistance and pressure. Secretions potentiate prolonged mechanical ventilation and ventilator-associated pneumonia. Our primary objective in this study was to evaluate an ETT-clearing device (ETT-CD) in its ability to remove secretions from ex vivo ETT lumens.

Methods: Forty ETTs, obtained from intensive care patients at extubation, were individually placed into a ventilator field performance testing simulator at 37°C. The pressure drop through the ETTs was measured at a flow rate of 60 L/min before and after cleaning with the ETT-CD and compared with unused, similarly sized controls tubes. The ETT-CD was inserted into an ETT until the tip reached Murphy's eye (hole in the side) of the ETT. The wiper, set back from the tip, was expanded by ETT-CD handle activation. As the ETT-CD was removed, the distal wiper extracted secretions from the ETT lumen.

Results: Forty ETTs were tested with nonparametric Wilcoxon signed-rank tests. Before being cleared with the ETT-CD, the median pressure drop in the extubated 7.5 mm ETTs was 17.8 cm H2O; after ETT-CD use, it was 12.3. The cleared ETTs were significantly improved over the ETTs before being cleared (p < 0.001); however, there remained a significant difference between the cleared ETTs and the control tubes (p=0.005), indicating the clearing was not to the level of an unused ETT. Similar results were determined for the 8.0 mm ETTs.

Conclusions: For the 7.5 mm and the 8.0 mm EETs, the ETT-CD improved effective patency of the ETTs over the uncleared ETTs, independent of occlusion location, tube size, or length of tube. However, there remained a significant difference between the cleared tubes and controls.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Filiberto D. M., Croce M. A. Surgical Critical Care Therapy 2018. Cham, Switzerland: Springer; 2018. Ventilator-associated pneumonia; pp. 407–413. - DOI
    1. Kollef M. H., Hamilton C. W., Ernst F. R. Economic impact of ventilator-associated pneumonia in a large matched cohort. Infection Control & Hospital Epidemiology. 2015;33(3):250–256. doi: 10.1086/664049. - DOI - PubMed
    1. Metersky M. L., Wang Y., Klompas M., Eckenrode S., Bakullari A., Eldridge N. Trend in ventilator-associated pneumonia rates between 2005 and 2013. JAMA. 2016;316(22):2427–2429. doi: 10.1001/jama.2016.16226. - DOI - PubMed
    1. Martin C., Thomachot L., Quinto B., Viviand X., Albanese J. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min. Chest. 1995;107(5):1411–1415. doi: 10.1378/chest.107.5.1411. - DOI - PubMed
    1. Kollef M. H. Prevention of ventilator-associated pneumonia or ventilator-associated complications. Critical Care Medicine. 2012;40(1):271–277. doi: 10.1097/ccm.0b013e318232e41d. - DOI - PubMed