Rapid microwave fixation--a comparative morphometric study
- PMID: 3065304
- DOI: 10.1007/BF01002728
Rapid microwave fixation--a comparative morphometric study
Abstract
Tissue blocks taken from healthy human lung tissues, from primary bronchial carcinoma and from mediastinal and hilar lymph nodes were placed in the following solutions: Tris buffer; buffered formalin (0.5%, 1%, 7%); 0.1 mol NaCl; distilled water; DMSO (1%, 10%, 20%); acetone (10%); methanol (50%, 80%, 100%); glutaraldehyde (2.5%), and fixed by use of a commercial microwave oven. Tissue blocks obtained from the same surgical specimens were fixed in 7% buffered formalin for 24 h for comparison. Conventional and microwave-fixed tissue was embedded in paraffin, and stained with haematoxylin and eosin. Fifteen specimens of each group and each solution were examined by light microscopy. Minimum diameter and area of 100 nuclei of each specimen were measured interactively. Histomorphological sections fixed with Tris buffer in a microwave oven revealed best morphological results showing more contrast in chromatin distribution of nuclei and 'opening' of interstitial lung capillaries in comparison to conventional formalin-fixed specimens. No statistically significant differences in area and minimum diameter of nuclei between the different groups were found. Microwave fixation using Tris buffer is a time-saving fixation method at least comparable to conventional formalin fixation. It is not accompanied by hazards to the environment that are unavoidable by formalin fixation.
Similar articles
-
Microwave fixation versus formalin fixation of surgical and autopsy tissue.Am J Med Technol. 1978 May;44(5):435-7. Am J Med Technol. 1978. PMID: 354379
-
Methods in pathology. p53 expression in formalin-fixed, paraffin-embedded archival specimens of intrahepatic cholangiocarcinoma: retrieval of p53 antigenicity by microwave oven heating of tissue sections.Mod Pathol. 1994 Feb;7(2):249-52. Mod Pathol. 1994. PMID: 8008749
-
Microwave processing for immunohistochemical demonstration of proliferating cell nuclear antigen (PCNA) in formalin-fixed and paraffin-embedded tissue.APMIS. 1994 May;102(5):395-400. doi: 10.1111/j.1699-0463.1994.tb04889.x. APMIS. 1994. PMID: 7912941
-
Microwave irradiation as a form of fixation for light and electron microscopy.J Pathol. 1985 Aug;146(4):313-21. doi: 10.1002/path.1711460404. J Pathol. 1985. PMID: 3897496
-
Lymph node harvest in colorectal adenocarcinoma specimens: the impact of improved fixation and examination procedures.APMIS. 2011 Jun;119(6):347-55. doi: 10.1111/j.1600-0463.2011.02748.x. Epub 2011 Apr 12. APMIS. 2011. PMID: 21569092 Review.
Cited by
-
Development of an ultrasound-emitting device for performing rapid immunostaining procedures.J Histochem Cytochem. 2010 May;58(5):421-8. doi: 10.1369/jhc.2010.955096. Epub 2010 Feb 1. J Histochem Cytochem. 2010. PMID: 20124095 Free PMC article.
-
Microwave stabilization versus chemical fixation. A morphometric study in glycolmethacrylate- and paraffin-embedded tissue.Histochem J. 1990 Jun-Jul;22(6-7):335-40. doi: 10.1007/BF01003166. Histochem J. 1990. PMID: 1698748
-
Isolating Viral and Host RNA Sequences from Archival Material and Production of cDNA Libraries for High-Throughput DNA Sequencing.Curr Protoc Microbiol. 2015 May 1;37:1E.8.1-16. doi: 10.1002/9780471729259.mc01e08s37. Curr Protoc Microbiol. 2015. PMID: 26344216 Free PMC article.
-
Immunocytology on microwave-fixed cells reveals rapid and agonist-specific changes in subcellular accumulation patterns for cAMP or cGMP.Proc Natl Acad Sci U S A. 1990 Feb;87(3):1188-92. doi: 10.1073/pnas.87.3.1188. Proc Natl Acad Sci U S A. 1990. PMID: 2153973 Free PMC article.
-
Comparison of Prostatic Tissue Processed by Microwave and Conventional Technique Using Morphometry.Iran J Pathol. 2015 Winter;10(1):1-8. Iran J Pathol. 2015. PMID: 26516319 Free PMC article.
References
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical
Miscellaneous