Total hip arthroplasty using stem-first technique with navigation: the potential of achievement of the optimal combined anteversion being a risk factor for anterior cup protrusion
Abstract
Purpose: In the combined anteversion (CA) technique for total hip arthroplasty (THA) with a cementless stem, cup anteversion is strongly influenced by the native femoral anteversion. It is hypothesized that in cases with large native femoral anteversion, cup anteversion can be decreased, and anterior cup protrusion from the anterior edge of the acetabulum could occur due to the achievement of optimal CA. In this study, the accuracy of CA in THA with the CA technique using imageless navigation and the relationship between the protrusion of the anterior edge of cup and optimum CA was retrospectively evaluated.
Methods: Ninety-seven patients (104 hips) who underwent primary THA by the CA technique using image-free navigation were enrolled in the study. The femoral stem was placed following the individual femoral anteversion so that the target cup anteversion could be determined following a mathematical formula (37 = femoral stem anteversion × 0.7 + cup anteversion). Results The resulting CA values effectively achieved accurate CA with 39.49 ± 5.03° postoperatively. On the other hand, anterior cup protrusion was measured by computed tomography image. A cup protrusion length of more than 3 mm was indicated for 60 cases (57.7%). All included patients were divided into two groups: Group 1 as protrusion positive and Group 2 as protrusion negative. In Group 1, preoperative femoral anteversion and postoperative stem anteversion were significantly higher, while postoperative cup anteversion was significantly lower. However, the postoperative CA value indicated no significant difference between the groups.
Conclusions: The CA (stem-first) technique with image-free navigated THA could effectively achieve accurate CA. On the other hand, a large number of cases revealed anterior cup protrusion due to the low cup anteversion.
Keywords: Combined anteversion; Cup protrusion; Imageless navigation; Stem-first THA.
Similar articles
-
New combined anteversion technique in hybrid THA: cup-first procedure with CT-based navigation.Eur J Orthop Surg Traumatol. 2020 Apr;30(3):465-472. doi: 10.1007/s00590-019-02589-y. Epub 2019 Nov 8. Eur J Orthop Surg Traumatol. 2020. PMID: 31705402
-
Accuracy of combined anteversion in image-free navigated total hip arthroplasty: stem-first or cup-first technique?Int Orthop. 2016 Jan;40(1):9-13. doi: 10.1007/s00264-015-2784-9. Epub 2015 May 7. Int Orthop. 2016. PMID: 25947898
-
Achievement of optimal implant alignment using taper wedge stems with cup-first THA through the MIS antero-lateral approach.Eur J Orthop Surg Traumatol. 2020 Dec;30(8):1505-1514. doi: 10.1007/s00590-020-02696-1. Epub 2020 Jul 7. Eur J Orthop Surg Traumatol. 2020. PMID: 32638123
-
Robotic arm-assisted total hip arthroplasty via a minimally invasive anterolateral approach in the supine position improves the precision of cup placement in patients with developmental dysplasia of the hip.J Orthop Sci. 2024 Mar;29(2):559-565. doi: 10.1016/j.jos.2023.01.012. Epub 2023 Feb 15. J Orthop Sci. 2024. PMID: 36801090 Review.
-
Imageless navigation for primary total hip arthroplasty: a meta-analysis study.J Orthop Traumatol. 2022 Apr 15;23(1):21. doi: 10.1186/s10195-022-00636-9. J Orthop Traumatol. 2022. PMID: 35426527 Free PMC article.
Cited by
-
3D Printed Guides and Preoperative Planning for Uncemented Stem Anteversion Reconstruction during Hip Arthroplasty: A Pilot Study.Biomed Res Int. 2021 Feb 19;2021:6621882. doi: 10.1155/2021/6621882. eCollection 2021. Biomed Res Int. 2021. Retraction in: Biomed Res Int. 2024 Mar 20;2024:9876580. doi: 10.1155/2024/9876580. PMID: 33681357 Free PMC article. Retracted.
-
New combined anteversion technique in hybrid THA: cup-first procedure with CT-based navigation.Eur J Orthop Surg Traumatol. 2020 Apr;30(3):465-472. doi: 10.1007/s00590-019-02589-y. Epub 2019 Nov 8. Eur J Orthop Surg Traumatol. 2020. PMID: 31705402
-
Component orientation measurements in total hip arthroplasty using an inertial measurement unit-based smart trial system.Arthroplasty. 2025 Jun 25;7(1):36. doi: 10.1186/s42836-025-00312-3. Arthroplasty. 2025. PMID: 40563123 Free PMC article.
-
Accuracy of Acetabular Cup Position Using CT Navigation During Total Hip Arthroplasty in Patients With Developmental Dysplasia of the Hip.Cureus. 2025 Jul 13;17(7):e87865. doi: 10.7759/cureus.87865. eCollection 2025 Jul. Cureus. 2025. PMID: 40809601 Free PMC article.
-
Morphological consistency of bilateral hip joints in adults based on the X-ray and CT data.Surg Radiol Anat. 2021 Jul;43(7):1107-1115. doi: 10.1007/s00276-020-02676-4. Epub 2021 Jan 23. Surg Radiol Anat. 2021. PMID: 33486573 Free PMC article.
References
MeSH terms
LinkOut - more resources