Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Apr;63(2):239-244.
doi: 10.1016/j.jpor.2018.12.006. Epub 2019 Jan 15.

Effects of number of metal restorations and mandibular position during computed tomography imaging on accuracy of maxillofacial models

Affiliations

Effects of number of metal restorations and mandibular position during computed tomography imaging on accuracy of maxillofacial models

Yumi Tsuchida et al. J Prosthodont Res. 2019 Apr.

Abstract

Purpose: Computed tomography (CT) imaging for three-dimensional (3D) printed models may improve the quality of surgical preoperative plans. Although metal objects can cause artifacts in CT images, integration of CT and digital dental arch imaging may solve this problem. The present study aimed to evaluate effects of the number of metal restorations and mandibular position during CT imaging on accuracy of reproduced models.

Methods: Stereolithography datasets from three sets of dental models having different numbers of metal restorations were obtained using a laboratory digitizing device (control) and CT equipment (nonintegrated data). CT scanning was performed under two conditions: intercuspal position (closed) and separated using paraffin wax (open). Nonintegrated data after metal artifact removal were separated into maxillary and mandibular dentition groups. The occlusal part of the control dentition and nonintegrated data were superimposed and integrated (integrated data). The root mean square (RMS) between the control and stereolithography data was calculated and analyzed with three-way analysis of variance and t-test with Bonferroni correction.

Results: Increasing numbers of metal restorations resulted in increase in metal artifacts and RMS values. Moreover, the RMS of the closed dataset was significantly greater than that of the open dataset because of the creation of artificial occlusal surfaces. The RMSs of the integrated datasets were significantly smaller than those of the nonintegrated datasets, except for the open model without metal restorations.

Conclusions: Accuracies of reproduced maxillary and mandibular models decreased with increasing numbers of metal restorations and in the closed mandibular position during CT scanning.

Keywords: Additive manufacturing; Computed tomography; Maxillofacial model; Maxillofacial surgery; Metal restoration.