. 2019 Feb;20(2):190-204.
doi: 10.3348/kjr.2018.0571.

User-Friendly Vendor-Specific Guideline for Pediatric Cardiothoracic Computed Tomography Provided by the Asian Society of Cardiovascular Imaging Congenital Heart Disease Study Group: Part 1. Imaging Techniques

Affiliations
Review

User-Friendly Vendor-Specific Guideline for Pediatric Cardiothoracic Computed Tomography Provided by the Asian Society of Cardiovascular Imaging Congenital Heart Disease Study Group: Part 1. Imaging Techniques

Sun Hwa Hong et al. Korean J Radiol. 2019 Feb.

Abstract

Optimal performance of pediatric cardiothoracic computed tomography (CT) is technically challenging and may need different approaches for different types of CT scanners. To meet the technical demands and improve clinical standards, a practical, user-friendly, and vendor-specific guideline for pediatric cardiothoracic CT needs to be developed for children with congenital heart disease (CHD). In this article, we have attempted to describe such guideline based on the consensus of experts in the Asian Society of Cardiovascular Imaging CHD Study Group. This first part describes the imaging techniques of pediatric cardiothoracic CT, and it includes recommendations for patient preparation, scan techniques, radiation dose, intravenous injection protocol, post-processing, and vendor-specific protocols.

Keywords: CT protocols; CT scan techniques; Child; Computed tomography; Congenital heart disease; Guideline; Intravenous injection protocols; Patient preparation; Post-processing; Radiation dose optimization.

PubMed Disclaimer

Conflict of interest statement

The authors have no financial conflicts of interest.

Similar articles

Cited by

References

    1. Han BK, Lesser AM, Vezmar M, Rosenthal K, Rutten-Ramos S, Lindberg J, et al. Cardiovascular imaging trends in congenital heart disease: a single center experience. J Cardiovasc Comput Tomogr. 2013;7:361–366. - PubMed
    1. Yang JC, Lin MT, Jaw FS, Chen SJ, Wang JK, Shih TT, et al. Trends in the utilization of computed tomography and cardiac catheterization among children with congenital heart disease. J Formos Med Assoc. 2015;114:1061–1068. - PMC - PubMed
    1. Lee T, Tsai IC, Fu YC, Jan SL, Wang CC, Chang Y, et al. Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol. 2006;36:1273–1282. - PubMed
    1. Goo HW. State-of-the-art CT imaging techniques for congenital heart disease. Korean J Radiol. 2010;11:4–18. - PMC - PubMed
    1. Goo HW. Cardiac MDCT in children: CT technology overview and interpretation. Radiol Clin North Am. 2011;49:997–1010. - PubMed