Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2019 Apr;143(4):1111-1118.
doi: 10.1097/PRS.0000000000005478.

Intramedullary Screw Fixation of Metacarpal Fractures Results in Excellent Functional Outcomes: A Literature Review

Affiliations
Meta-Analysis

Intramedullary Screw Fixation of Metacarpal Fractures Results in Excellent Functional Outcomes: A Literature Review

Christina M Beck et al. Plast Reconstr Surg. 2019 Apr.

Abstract

Background: Intramedullary fixation of a comminuted subcapital metacarpal fracture using a headless compression screw was first described in 2010. The purpose of this study was to identify and evaluate all studies reporting clinical outcomes of intramedullary screw fixation of metacarpal fractures.

Methods: A comprehensive search of the literature was performed under Preferred Reporting Items for Systematic Review and Meta-Analyses guidelines to identify all relevant studies. Outcome measures included mean follow-up, evidence of radiographic union, functional outcomes, and quality-of-life measures.

Results: Nine articles for a total of 169 metacarpal fractures were identified. Average patient age was 32 years; 86.5 percent of the patients were men; and the majority of fractures occurred in the small finger (74 percent). Most fractures occurred in the neck (n = 66), followed by shaft (n = 31) and head (n = 10). The average follow-up was 11 months, with an average metacarpophalangeal joint flexion of 86 degrees (n = 83) and digit total active motion of 251 degrees (n = 72). Radiographic union was achieved in 100% of reported cases (n = 132) at or before the latest follow-up. Grip strength in four studies showed an average of 96 percent compared to the contralateral hand. No serious complications were reported. Nine minor complications were reported, including four cases of hardware removal in asymptomatic patients.

Conclusion: The review of the literature suggests intramedullary fixation of metacarpal neck and shaft fractures using headless compression screws has thus far proven to be a safe and successful surgical treatment option resulting in excellent clinical outcomes.

PubMed Disclaimer

Comment in

Similar articles

Cited by

References

    1. Nakashian MN, Pointer L, Owens BD, Wolf JM. Incidence of metacarpal fractures in the US population. Hand (N Y) 2012;7:426–430.
    1. Gudmundsen TE, Borgen L. Fractures of the fifth metacarpal. Acta Radiol. 2009;50:296–300.
    1. Stern PJ. Management of fractures of the hand over the last 25 years. J Hand Surg Am. 2000;25:817–823.
    1. Friedrich JB, Vedder NB. An evidence-based approach to metacarpal fractures. Plast Reconstr Surg. 2010;126:2205–2209.
    1. Boulton CL, Salzler M, Mudgal CS. Intramedullary cannulated headless screw fixation of a comminuted subcapital metacarpal fracture: Case report. J Hand Surg Am. 2010;35:1260–1263.

LinkOut - more resources