Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Mar;411(7):1421-1431.
doi: 10.1007/s00216-019-01581-z. Epub 2019 Jan 25.

Non-target data acquisition for target analysis (nDATA) of 845 pesticide residues in fruits and vegetables using UHPLC/ESI Q-Orbitrap

Affiliations

Non-target data acquisition for target analysis (nDATA) of 845 pesticide residues in fruits and vegetables using UHPLC/ESI Q-Orbitrap

Jian Wang et al. Anal Bioanal Chem. 2019 Mar.

Abstract

A non-target data acquisition for target analysis (nDATA) workflow based on accurate mass measurements using UHPLC/ESI Q-Orbitrap full MS-data-independent acquisition and a compound database was developed to screen pesticide residues in fruit and vegetable samples. The compound database of 845 pesticides was built from dd-MS2 (data-dependent acquisition) product ion spectral data and LC retention times of individual pesticide standards. MS2 spectra of samples were acquired using multiplexing data-independent acquisition (mDIA) and variable data-independent acquisition (vDIA). Screening of pesticides in samples was based on either the retention time (± 0.5 min) and the mass accuracy (± 5 ppm) of a precursor (RTP by full MS) or the retention time (± 0.5 min) and the mass accuracy (± 5 ppm) of a precursor and its fragment ion (RTFI by full MS/DIA). In validation studies involving mDIA and vDIA analysis of 10 fruits and vegetables spiked with pesticides prior to QuEChERS sample preparation, RTP correctly found up to 765 and 796 pesticides at 10 and 100 μg/kg, respectively, whereas RTFI correctly identified up to 729 and 764 pesticides at the same respective concentrations. UHPLC/ESI Q-Orbitrap full MS/mDIA or vDIA proved to be a comprehensive detection technique and has potential for pesticide residue screening in fruits and vegetables. Graphical Abstract.

Keywords: Multiplexing data-independent acquisition (mDIA); Pesticide residues; UHPLC/ESI Q-Orbitrap; Variable data-independent acquisition (vDIA); nDATA.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources