Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2019 May:57:266-271.
doi: 10.1016/j.avsg.2018.09.044. Epub 2019 Jan 24.

The "Destino-guided BEVAR" to Catheterize Downward Branches from a Femoral Access: Technical Note and Case Report

Affiliations
Case Reports

The "Destino-guided BEVAR" to Catheterize Downward Branches from a Femoral Access: Technical Note and Case Report

Matteo Orrico et al. Ann Vasc Surg. 2019 May.

Abstract

Background: The aim of this study is to report the Destino-guided branched endovascular aortic repair approach as a valid alternative to catheterization downward branches in complex aortic arch/descending thoracic anatomies.

Methods & results: A 53-year-old woman with Marfan syndrome underwent a thoracoabdominal aortic aneurysm (TAAA) repair for a type III dissecting aneurysm. A custom repair with an endograft having 3 fenestrations (for renal arteries and superior mesenteric artery) and 1 branch for the celiac trunk was planned. The right axillary artery was chronically occluded; the left subclavian artery (LSA) was aneurysmatic. The catheterization of the celiac trunk branch was demanding but ultimately a bare stent was used as a bridging component between the graft and the target vessel, for spinal cord preconditioning. At the 2-month computed tomography angiography, when planning the relining of the bare metal stent, a 1 cm increase in diameter of the LSA aneurysm was documented and therefore a Destino-guided branched endovascular aortic repair was planned. This approach consists of branch catheterization via femoral access using the Destino steerable guiding sheath inside which, after bending, a smaller Cook Flexor is placed to easily deliver the stent, while maintaining stability.

Conclusions: The Destino-guided branched endovascular aortic repair is a reproducible and effective alternative to the classic catheterization of side branches via brachial/axillary access allowing their completion from a femoral access.

PubMed Disclaimer

Publication types

MeSH terms

LinkOut - more resources