The use of dense alumina-alumina ceramic combination in total hip replacement
- PMID: 3069846
- DOI: 10.1002/jbm.820221210
The use of dense alumina-alumina ceramic combination in total hip replacement
Abstract
The purpose of this article was to review the laboratory and clinical performances since 1970 of a total hip prosthesis using alumina-alumina combination. The chemical and physical properties of dense alumina ceramic were studied in relation to biocompatibility, mechanical strength, and surface properties. Through the examination of 35 retrieved implants, it was found that the long-term success of alumina-alumina total hip replacement depends on both the ceramic microstructure (small grain size with uniform distribution, minimum porosity, absence of inclusions) and implant geometry (sphericity deviation +/- 1 micron, radius tolerance between components 7-10 microns). Alumina component wear and fractures have disappeared with the use of high-performance materials and severe manufacturing quality control. Examination of human biopsies from well-fixed prostheses showed that alumina particles deposits increase with time with only a low-grade macrophagic reaction. When loosening occurred, an inflammatory reaction appeared; this reaction was less striking than with loose metal-polyethylene prostheses, however. The long-term behavior of cementless alumina cup fixation depends upon initial positioning and stability; survivorship analysis of the cemented ceramic cups showed an 88% survival probability after 8 years with a 1.6% average annual probability of revision. The percentage of surviving was 100% after 8 years in patients who were less than 50 years old. Aseptic loosenings occurring at the cup-cement interface were assumed to be related to stress protection secondary to the high rigidity of the ceramic leading to a weakening of the spongious bone supporting the cement mantle. Good bone stock quality as well as high-quality ceramic appear to be the prerequisites for durable fixation of alumina sockets.
Similar articles
-
Conus hip prosthesis.Acta Chir Orthop Traumatol Cech. 2001;68(4):213-21. Acta Chir Orthop Traumatol Cech. 2001. PMID: 11706545
-
Alternative materials to improve total hip replacement tribology.Acta Orthop Scand. 2003 Aug;74(4):380-8. doi: 10.1080/00016470310017668. Acta Orthop Scand. 2003. PMID: 14521286 Review.
-
All-ceramic fixed partial dentures. Studies on aluminum oxide- and zirconium dioxide-based ceramic systems.Swed Dent J Suppl. 2005;(173):1-69. Swed Dent J Suppl. 2005. PMID: 16001730
-
[Cementless acetabular fixation with solid alumina sockets. Apropos of 62 total hybrid prostheses with press-fit alumina sockets at 6-year mean follow-up].Rev Chir Orthop Reparatrice Appar Mot. 2000 Sep;86(5):474-81. Rev Chir Orthop Reparatrice Appar Mot. 2000. PMID: 10970971 Clinical Trial. French.
-
Role of ceramic implants. Design and clinical success with total hip prosthetic ceramic-to-ceramic bearings.Clin Orthop Relat Res. 1992 Sep;(282):19-30. Clin Orthop Relat Res. 1992. PMID: 1516312 Review.
Cited by
-
Prostaglandin E2 level in tissue surrounding aseptic failed total hips. Effects of materials.Arch Orthop Trauma Surg. 1992;111(5):255-8. doi: 10.1007/BF00571519. Arch Orthop Trauma Surg. 1992. PMID: 1389776
-
Influence of Metallic Deposition on Ceramic Femoral Heads on the Wear Behavior of Artificial Hip Joints: A Simulator Study.Materials (Basel). 2020 Aug 12;13(16):3569. doi: 10.3390/ma13163569. Materials (Basel). 2020. PMID: 32806756 Free PMC article.
-
A squeaky reputation: the problem may be design-dependent.Clin Orthop Relat Res. 2011 Jun;469(6):1598-605. doi: 10.1007/s11999-011-1777-2. Clin Orthop Relat Res. 2011. PMID: 21274762 Free PMC article.
-
Seating of ceramic liners in the uncemented trident acetabular shell: is there really a problem?Clin Orthop Relat Res. 2009 Oct;467(10):2651-5. doi: 10.1007/s11999-009-0974-8. Epub 2009 Jul 7. Clin Orthop Relat Res. 2009. PMID: 19582522 Free PMC article.
-
Clinical Faceoff: Instability After THA: The Potential Role of the Bearing Surface.Clin Orthop Relat Res. 2018 Apr;476(4):678-683. doi: 10.1007/s11999.0000000000000162. Clin Orthop Relat Res. 2018. PMID: 29543657 Free PMC article. No abstract available.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Other Literature Sources