Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2019 Apr;145(1):47-53.
doi: 10.1002/ijgo.12770. Epub 2019 Feb 20.

Two-dimensional fetal biometry versus three-dimensional fractional thigh volume for ultrasonographic prediction of birthweight

Affiliations
Observational Study

Two-dimensional fetal biometry versus three-dimensional fractional thigh volume for ultrasonographic prediction of birthweight

K Aparna Sharma et al. Int J Gynaecol Obstet. 2019 Apr.

Abstract

Objective: To develop and validate birthweight prediction models using fetal fractional thigh volume (TVol) in an Indian population, comparing them with existing prediction models developed for other ethnicities.

Methods: A prospective observational study was conducted among 131 pregnant women (>36 weeks) attending a tertiary hospital in New Delhi, India, for prenatal care between December 1, 2014, and November 1, 2016. Participants were randomly divided into formulating (n=100) and validation (n=31) groups. Multiple regression analysis was performed to generate four models to predict birthweight using various combinations of two-dimensional (2D) ultrasonographic parameters and a three-dimensional (3D) ultrasonographic parameter (TVol). The best fit model was compared with previously published 2D and 3D models.

Results: The best fit model comprised biparietal diameter, head circumference, abdominal circumference, and TVol. This model had the lowest mean percentage error (0.624 ± 8.075) and the highest coefficient of determination (R2 =0.660). It correctly predicted 70.2% and 91.6% of birthweights within 5% and 10% of actual weight, respectively. Compared with previous models, attributability for the 2D and 3D models was 0.65 and 0.55, respectively. Accuracy was -0.05 ± 1.007 and -2.54 ± 1.11, respectively.

Conclusion: Models that included TVol provided good prediction of birthweight in the target population.

Keywords: Birthweight prediction; Fractional thigh volume; Three dimensional ultrasound.

PubMed Disclaimer

Publication types

LinkOut - more resources