Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2020 Jan;34(1):134-144.
doi: 10.1519/JSC.0000000000003064.

Assessment of a Novel Algorithm to Determine Change-of-Direction Angles While Running Using Inertial Sensors

Affiliations

Assessment of a Novel Algorithm to Determine Change-of-Direction Angles While Running Using Inertial Sensors

Aaron S Balloch et al. J Strength Cond Res. 2020 Jan.

Abstract

Balloch, AS, Meghji, M, Newton, RU, Hart, NH, Weber, JA, Ahmad, I, and Habibi, D. Assessment of a novel algorithm to determine change-of-direction angles while running using inertial sensors. J Strength Cond Res 34(1): 134-144, 2020-The ability to detect and quantify change-of-direction (COD) movement may offer a unique approach to load-monitoring practice. Validity and reliability of a novel algorithm to calculate COD angles for predetermined COD movements ranging from 45 to 180° in left and right directions was assessed. Five recreationally active men (age: 29.0 ± 0.5 years; height: 181.0 ± 5.6 cm; and body mass: 79.4 ± 5.3 kg) ran 5 consecutive predetermined COD trials each, at 4 different angles (45, 90, 135, and 180°), in each direction. Participants were fitted with a commercially available microtechnology unit where inertial sensor data were extracted and processed using a novel algorithm designed to calculate precise COD angles for direct comparison with a high-speed video (remotely piloted, position-locked aircraft) criterion measure. Validity was assessed using Bland-Altman 95% limits of agreement and mean bias. Reliability was assessed using typical error (expressed as a coefficient of variation [CV]). Concurrent validity was present for most angles. Left: (45° = 43.8 ± 2.0°; 90° = 88.1 ± 2.0°; 135° = 136.3 ± 2.1°; and 180° = 181.8 ± 2.5°) and Right: (45° = 46.3 ± 1.6°; 90° = 91.9 ± 2.2°; 135° = 133.4 ± 2.0°; 180° = 179.2 ± 5.9°). All angles displayed excellent reliability (CV < 5%) while greater mean bias (3.6 ± 5.1°, p < 0.001), weaker limits of agreement, and reduced precision were evident for 180° trials when compared with all other angles. High-level accuracy and reliability when detecting COD angles further advocates the use of inertial sensors to quantify sports-specific movement patterns.

PubMed Disclaimer

References

    1. Aughey RJ. Applications of GPS technologies to field sports. Int J Sports Physiol Perform 6: 295–310, 2011.
    1. Bland MJ, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 327: 307–310, 1986.
    1. Bonomi AG, Goris AH, Yin B, Westerterp KR. Detection of type, duration, and intensity of physical activity using an accelerometer. Med Sci Sports Exerc 41: 1770–1777, 2009.
    1. Boyd LJ, Ball K, Aughey RJ. The reliability of MinimaxX accelerometers for measuring physical activity in Australian football. Int J Sports Physiol Perform 6: 311–321, 2011.
    1. Boyd LJ, Ball K, Aughey RJ. Quantifying external load in Australian football matches and training using accelerometers. Int J Sports Physiol Perform 8: 44–51, 2013.

LinkOut - more resources