Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jul-Aug;100(7-8):445-453.
doi: 10.1016/j.diii.2019.01.004. Epub 2019 Jan 31.

Ultrasonographic guidance for portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) placement

Affiliations

Ultrasonographic guidance for portal vein access during transjugular intrahepatic portosystemic shunt (TIPS) placement

A David et al. Diagn Interv Imaging. 2019 Jul-Aug.

Abstract

Purpose: The purpose of our study was to retrospectively assess the safety and efficacy of percutaneous real-time ultrasound guidance for portal vein puncture during transjugular intrahepatic portosystemic shunt (TIPS) placement.

Materials and methods: Between January 2011 and November 2018, procedure details and outcome were retrospectively analyzed for 224 patients who underwent TIPS placement using real-time ultrasound guidance for portal vein puncture. There were 175 men and 49 women with a mean age of 52.7±10.6 (SD) years (range: 22-82 years). For each procedure, technical success, primary ultrasound guidance success, portosystemic pressure gradient, duration of the intervention, procedural complications, radiation exposure, mortality and morbidity rates at day 30 post-procedure were recorded for data analysis.

Results: Technical success rate was 100.0% with a success rate of the primary ultrasound guidance of 97.8% (219/224; 95% CI: 95.8-99.7). Mean duration of the procedure was 86.2±41.7 (SD) min (range: 22.0-267.0min). Mean dose-area product was 62.0±50.2 (SD) Gy.cm2 (range: 3.7-306.5Gy.cm2). Twelve complications (12/224; 5.4%) occurred in ten patients during TIPS procedures including 8 arterial punctures (3.6%) and 4 biliary punctures (1.8%). Four complications (4/224; 1.8%) were clinically significant. Mortality rate at day 30 after the procedure was 9.8% (22/224), without any patient dying from technical complications.

Conclusion: Real-time ultrasound guidance is a safe technique to assist in the creation of TIPS and may allow for lower radiation exposure.

Keywords: Imaging guidance; Portal hypertension; Portal vein puncture; Transjugular intrahepatic portosystemic shunt (TIPS); Ultrasound.

PubMed Disclaimer

LinkOut - more resources