Regional distribution of chest wall displacements in infants during high-frequency ventilation

Affiliations
Free article

Regional distribution of chest wall displacements in infants during high-frequency ventilation

Emanuela Zannin et al. J Appl Physiol (1985). .
Free article

Abstract

The distribution of ventilation during high-frequency ventilation (HFV) is asynchronous, nonhomogeneous, and frequency dependent. We hypothesized that differences in the regional distribution of ventilation at different oscillatory frequencies may affect gas exchange efficiency. We studied 15 newborn infants with a median gestational age of 28.9 (26.4-30.3) wk and body weight of 1.0 (0.8-1.4) kg. Five ventilation frequencies (5, 8, 10, 12, and 15 Hz) were tested, keeping carbon dioxide diffusion coefficient constant. The displacements of 24 passive markers placed on the infant's chest wall were measured by optoelectronic plethysmography. We evaluated the amplitude and phase shift of displacements of single markers placed along the midline and the regional displacements of the chest wall surface. Blood gases were unaffected by frequency. Chest wall volume changes decreased from 1.6 (0.4) ml/kg at 5 Hz to 0.7 ml/kg at 15 Hz. At all frequencies, the abdomen (AB) oscillated more markedly than the ribcage (RC). The mean (SD) AB/RC ratio was 1. 95 (0.7) at 5 Hz, increased to 2.1 (1.3) at 10 Hz, and then decreased to 1.1 (0.5) at 15 Hz ( P < 0.05 vs. 10 Hz). Volume changes in the AB lagged the RC and this phase shift increased with frequency. The AB oscillated more than the RC at all frequencies. Regional oscillations were highly inhomogeneous up to 10 Hz, and they became progressively more asynchronous with increasing frequency. When the carbon dioxide diffusion coefficient is held constant, such differences in regional chest wall expansion do not affect gas exchange. NEW & NOTEWORTHY We characterized the regional distribution of chest wall displacements in infants receiving high-frequency oscillatory ventilation at different frequencies. When carbon dioxide diffusion coefficient is held constant, there is no combination of frequency and tidal volume that optimizes gas exchange. The relative displacement between different chest wall compartments is not affected by frequency. However, at high frequencies, chest wall displacements are lower, with the potential to reduce total and regional overdistension without affecting gas exchange.

Keywords: chest wall displacements; high frequency ventilation; infant.