Assessment of the Xpert MTB/RIF Ultra assay on rapid diagnosis of extrapulmonary tuberculosis

Affiliations
Free article

Assessment of the Xpert MTB/RIF Ultra assay on rapid diagnosis of extrapulmonary tuberculosis

Xiaocui Wu et al. Int J Infect Dis. 2019 Apr.
Free article

Abstract

Objective: To evaluate the diagnostic performance of Xpert MTB/RIF Ultra for EPTB (Extrapulmonary Tuberculosis) patients on different types of extrapulmonary specimens from different anatomic sites.

Methods: Patients with suspected EPTB were prospectively included, extrapulmonary specimens were collected and subjected to culture, Xpert and Xpert Ultra assays in accordance with relevant guidelines.

Results: A total of 225 cases were included which contained 200 EPTB cases (43 culture-positive EPTB, 157 culture-negative EPTB which were diagnosed based on pathological results and a satisfied response to anti-TB treatment) and 25 non-EPTB cases. Sensitivities of Xpert Ultra and Xpert for culture-positive cases were 83.7% (95%CI, 68.7-92.7) and 67.4% (95% CI, 51.3-80.5) respectively. Specificities of Xpert Ultra and Xpert were 92.0% (95% CI, 72.5-98.6) and 96.0% (95% CI, 77.7-99.8) respectively. The sensitivities of Xpert Ultra, Xpert and culture for 200 EPTB cases were 52.5% (105/200, 95% CI, 45.4-59.6), 34.0% (68/200, 95% CI, 27.6-41.1) and 21.5% (43/200, 95% CI, 16.2-28.0) respectively. By comparison among different types of specimens, Xpert Ultra can detect 78.9% (56/71) of EPTB on fine-needle aspiration (FNA) tissues which was higher than that on pleural fluid (43.7% (45/103), p<0.05.

Conclusions: Xpert Ultra assay had a higher sensitivity than those of Xpert and culture on extrapulmonary specimens, which could be a promising approach for rapid EPTB diagnosis.

Keywords: Diagnosis; Extrapulmonary tuberculosis; Mycobacterium tuberculosis; Xpert MTB/RIF; Xpert MTB/RIF Ultra.