. 2019 Apr;30(4):615-624.
doi: 10.1007/s13361-018-02130-1. Epub 2019 Feb 13.

Applications of Direct Injection Soft Chemical Ionisation-Mass Spectrometry for the Detection of Pre-blast Smokeless Powder Organic Additives

Affiliations

Applications of Direct Injection Soft Chemical Ionisation-Mass Spectrometry for the Detection of Pre-blast Smokeless Powder Organic Additives

Ramón González-Méndez et al. J Am Soc Mass Spectrom. 2019 Apr.

Abstract

Analysis of smokeless powders is of interest from forensics and security perspectives. This article reports the detection of smokeless powder organic additives (in their pre-detonation condition), namely the stabiliser diphenylamine and its derivatives 2-nitrodiphenylamine and 4-nitrodiphenylamine, and the additives (used both as stabilisers and plasticisers) methyl centralite and ethyl centralite, by means of swab sampling followed by thermal desorption and direct injection soft chemical ionisation-mass spectrometry. Investigations on the product ions resulting from the reactions of the reagent ions H3O+ and O2+ with additives as a function of reduced electric field are reported. The method was comprehensively evaluated in terms of linearity, sensitivity and precision. For H3O+, the limits of detection (LoD) are in the range of 41-88 pg of additive, for which the accuracy varied between 1.5 and 3.2%, precision varied between 3.7 and 7.3% and linearity showed R2 ≥ 0.9991. For O2+, LoD are in the range of 72 to 1.4 ng, with an accuracy of between 2.8 and 4.9% and a precision between 4.5 and 8.6% and R2 ≥ 0.9914. The validated methodology was applied to the analysis of commercial pre-blast gun powders from different manufacturers. Graphical Abstract.

Keywords: PTR-MS; Proton transfer reaction mass spectrometry; SCIMS; Smokeless powder additives; Smokeless powders; Soft chemical ionisation-mass spectrometry.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Analyst. 2001 Apr;126(4):480-4 - PubMed
    1. J Forensic Sci. 2003 Sep;48(5):961-72 - PubMed
    1. Electrophoresis. 2004 Jun;25(10-11):1543-7 - PubMed
    1. J Chromatogr A. 2004 Dec 24;1061(2):225-33 - PubMed
    1. Forensic Sci Int. 2006 Apr 20;158(1):39-51 - PubMed

LinkOut - more resources