Applications of Direct Injection Soft Chemical Ionisation-Mass Spectrometry for the Detection of Pre-blast Smokeless Powder Organic Additives
- PMID: 30761477
- DOI: 10.1007/s13361-018-02130-1
Applications of Direct Injection Soft Chemical Ionisation-Mass Spectrometry for the Detection of Pre-blast Smokeless Powder Organic Additives
Abstract
Analysis of smokeless powders is of interest from forensics and security perspectives. This article reports the detection of smokeless powder organic additives (in their pre-detonation condition), namely the stabiliser diphenylamine and its derivatives 2-nitrodiphenylamine and 4-nitrodiphenylamine, and the additives (used both as stabilisers and plasticisers) methyl centralite and ethyl centralite, by means of swab sampling followed by thermal desorption and direct injection soft chemical ionisation-mass spectrometry. Investigations on the product ions resulting from the reactions of the reagent ions H3O+ and O2+ with additives as a function of reduced electric field are reported. The method was comprehensively evaluated in terms of linearity, sensitivity and precision. For H3O+, the limits of detection (LoD) are in the range of 41-88 pg of additive, for which the accuracy varied between 1.5 and 3.2%, precision varied between 3.7 and 7.3% and linearity showed R2 ≥ 0.9991. For O2+, LoD are in the range of 72 to 1.4 ng, with an accuracy of between 2.8 and 4.9% and a precision between 4.5 and 8.6% and R2 ≥ 0.9914. The validated methodology was applied to the analysis of commercial pre-blast gun powders from different manufacturers. Graphical Abstract.
Keywords: PTR-MS; Proton transfer reaction mass spectrometry; SCIMS; Smokeless powder additives; Smokeless powders; Soft chemical ionisation-mass spectrometry.
Similar articles
-
Analysis of the headspace composition of smokeless powders using GC-MS, GC-μECD and ion mobility spectrometry.Forensic Sci Int. 2011 May 20;208(1-3):29-36. doi: 10.1016/j.forsciint.2010.10.024. Epub 2010 Nov 24. Forensic Sci Int. 2011. PMID: 21109373
-
Detection of odor signatures of smokeless powders using solid phase microextraction coupled to an ion mobility spectrometer.Forensic Sci Int. 2009 Jul 1;188(1-3):112-8. doi: 10.1016/j.forsciint.2009.03.032. Epub 2009 May 1. Forensic Sci Int. 2009. PMID: 19410393
-
Characterization of smokeless powders using nanoelectrospray ionization mass spectrometry (nESI-MS).Anal Bioanal Chem. 2009 Aug;394(8):2019-28. doi: 10.1007/s00216-009-2689-9. Epub 2009 Feb 26. Anal Bioanal Chem. 2009. PMID: 19242680
-
Photo-ionisation mass spectrometry as detection method for gas chromatography. Optical selectivity and multidimensional comprehensive separations.J Chromatogr A. 2008 Mar 14;1184(1-2):296-308. doi: 10.1016/j.chroma.2007.08.081. Epub 2007 Sep 11. J Chromatogr A. 2008. PMID: 17915237 Review.
-
Recent developments of proton-transfer reaction mass spectrometry (PTR-MS) and its applications in medical research.Mass Spectrom Rev. 2013 Mar-Apr;32(2):143-65. doi: 10.1002/mas.21357. Epub 2012 Oct 23. Mass Spectrom Rev. 2013. PMID: 23097015 Review.
Cited by
-
Vapor Signatures of Double-Base Smokeless Powders and Gunshot Residues for Supporting Canine Odor Imprinting.ACS Omega. 2022 Jun 17;7(26):22567-22576. doi: 10.1021/acsomega.2c01882. eCollection 2022 Jul 5. ACS Omega. 2022. PMID: 35811902 Free PMC article.
-
Interpol review of the analysis and detection of explosives and explosives residues.Forensic Sci Int Synerg. 2023 Jan 13;6:100298. doi: 10.1016/j.fsisyn.2022.100298. eCollection 2023. Forensic Sci Int Synerg. 2023. PMID: 36685733 Free PMC article. Review. No abstract available.
-
Selective Reagent Ion Mass Spectrometric Investigations of the Nitroanilines.J Am Soc Mass Spectrom. 2019 Nov;30(11):2259-2266. doi: 10.1007/s13361-019-02325-0. Epub 2019 Sep 9. J Am Soc Mass Spectrom. 2019. PMID: 31502221 Free PMC article.
References
Grants and funding
LinkOut - more resources
Full Text Sources
Research Materials