. 2021 Feb;28(1):90-99.
doi: 10.1007/s12350-019-01643-w. Epub 2019 Feb 14.

Semi-quantitative indices of cardiac uptake in patients with suspected cardiac amyloidosis undergoing 99mTc-HMDP scintigraphy

Affiliations

Semi-quantitative indices of cardiac uptake in patients with suspected cardiac amyloidosis undergoing 99mTc-HMDP scintigraphy

Chiara Gallini et al. J Nucl Cardiol. 2021 Feb.

Abstract

Background: 99mTc-HMDP scintigraphy has proved its efficacy in non-invasive diagnosis of cardiac amyloidosis (CA) and is currently interpreted according to the Perugini qualitative assessment. Several semi-quantitative indices have been proposed to overcome inherent possible limitations of visual grading. Our aim was to comparatively evaluate six different indices and their diagnostic performance.

Methods: We retrospectively reviewed scintigraphy of 76 patients (53 ATTR, 12 AL, 11 LVH) who underwent diagnostic evaluation at our centre. ROC-curve analysis was performed to identify optimal cut-off and relative diagnostic accuracy of six different indices (of which one was proposed for the first time), both in identifying CA patients and in discriminating patients according to their Perugini score.

Results: Heart/Whole-body ratios proved to be the most accurate (100%) in identifying CA patients. Heart/Pelvis ratio (with soft tissue background correction) offered acceptable accuracy (98%), with the largest area under the curve (AUC) (0.98) in discriminating patients with Perugini ≥ 2. Heart/Contralateral Lung ratio confirmed to be exposed to confounding background noise in case of simultaneous lung uptake. Heart/Skull ratio had the worst performance, with six false-negative patients in ATTR identification.

Conclusion: Heart/Whole-body ratios may be robust and effective semi-quantitative indices for the evaluation of CA by means of scintigraphy.

Keywords: Amyloid heart disease; SPECT; molecular imaging agents.

PubMed Disclaimer

Comment in

References

    1. Perfetto F, Cappelli F, Bergesio F, Ciuti G, Porciani MC, Padeletti L. Moggi pignone a cardiac amyloidosis: The heart of the matter. Intern Emerg Med 2013;8:191-203. - DOI
    1. Perugini E, Guidalotti PL, Salvi F, Cooke RM, Pettinato C, Riva L, et al. Noninvasive etiologic diagnosis of cardiac amyloidosis using 99 mTc-3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy. J Am Coll Cardiol 2005;46:1076-84. - DOI
    1. Rapezzi C, Quarta CC, Guidalotti PL, Pettinato C, Fanti S, Leone O, et al. Role of (99m)Tc-DPD scintigraphy in diagnosis and prognosis of hereditary transthyretin related cardiac amyloidosis. JACC Cardiovasc Imaging 2011;4:659-70. - DOI
    1. Longhi S, Guidalotti PL, Quarta CC, Gagliardi C, Milandri A, Lorenzini M, Potena L, et al. Identification of TTR related subclinical amyloidosis with 99mTc-DPD scintigraphy. JACC Cardiovasc Imaging 2014;7:531-2. - DOI
    1. Hutt DF, Quigley AM, Page J, Hall ML, Burniston M, Gopaul D, et al. Utility and limitations of 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy in systemic amyloidosis. Eur Heart J Cardiovasc Imaging. 2014;15:1289-98. - DOI

Substances