Review
. 2019 Feb 15;7(2):e11606.
doi: 10.2196/11606.

The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review

Affiliations
Review

The Current State of Mobile Phone Apps for Monitoring Heart Rate, Heart Rate Variability, and Atrial Fibrillation: Narrative Review

Ka Hou Christien Li et al. JMIR Mhealth Uhealth. .

Abstract

Background: Mobile phone apps capable of monitoring arrhythmias and heart rate (HR) are increasingly used for screening, diagnosis, and monitoring of HR and rhythm disorders such as atrial fibrillation (AF). These apps involve either the use of (1) photoplethysmographic recording or (2) a handheld external electrocardiographic recording device attached to the mobile phone or wristband.

Objective: This review seeks to explore the current state of mobile phone apps in cardiac rhythmology while highlighting shortcomings for further research.

Methods: We conducted a narrative review of the use of mobile phone devices by searching PubMed and EMBASE from their inception to October 2018. Potentially relevant papers were then compared against a checklist for relevance and reviewed independently for inclusion, with focus on 4 allocated topics of (1) mobile phone monitoring, (2) AF, (3) HR, and (4) HR variability (HRV).

Results: The findings of this narrative review suggest that there is a role for mobile phone apps in the diagnosis, monitoring, and screening for arrhythmias and HR. Photoplethysmography and handheld electrocardiograph recorders are the 2 main techniques adopted in monitoring HR, HRV, and AF.

Conclusions: A number of studies have demonstrated high accuracy of a number of different mobile devices for the detection of AF. However, further studies are warranted to validate their use for large scale AF screening.

Keywords: arrhythmia; atrial fibrillation; electrocardiography; heart rate; mobile health; mobile phone apps; photoplethysmography.

PubMed Disclaimer

Conflict of interest statement

Conflicts of Interest: None declared.

Figures

Figure 1
Figure 1
(A) Patient setup; (B) cardiioRhythm app facial photoplethysmography analysis interface; and (C) complete facial photoplethysmography signals report.

References

    1. Artinian NT, Fletcher GF, Mozaffarian D, Kris-Etherton P, Van Horn L, Lichtenstein AH, Kumanyika S, Kraus WE, Fleg JL, Redeker NS, Meininger JC, Banks J, Stuart-Shor EM, Fletcher BJ, Miller TD, Hughes S, Braun LT, Kopin LA, Berra K, Hayman LL, Ewing LJ, Ades PA, Durstine JL, Houston-Miller N, Burke LE, American Heart Association Prevention Committee of the Council on Cardiovascular Nursing Interventions to promote physical activity and dietary lifestyle changes for cardiovascular risk factor reduction in adults: a scientific statement from the American Heart Association. Circulation. 2010 Jul 27;122(4):406–41. doi: 10.1161/CIR.0b013e3181e8edf1. http://circ.ahajournals.org/cgi/pmidlookup?view=long&pmid=20625115 CIR.0b013e3181e8edf1 - DOI - PMC - PubMed
    1. Moerenhout T, Devisch I, Cornelis GC. E-health beyond technology: analyzing the paradigm shift that lies beneath. Med Health Care Philos. 2018 Mar;21(1):31–41. doi: 10.1007/s11019-017-9780-3.10.1007/s11019-017-9780-3 - DOI - PubMed
    1. Appelboom G, LoPresti M, Reginster JY, Sander Connolly E, Dumont EP. The quantified patient: a patient participatory culture. Curr Med Res Opin. 2014 Dec;30(12):2585–7. doi: 10.1185/03007995.2014.954032. - DOI - PubMed
    1. Martin SS, Feldman DI, Blumenthal RS, Jones SR, Post WS, McKibben RA, Michos ED, Ndumele CE, Ratchford EV, Coresh J, Blaha MJ. mActive: a randomized clinical trial of an automated mHealth intervention for physical activity promotion. J Am Heart Assoc. 2015 Nov 9;4(11) doi: 10.1161/JAHA.115.002239. http://jaha.ahajournals.org/cgi/pmidlookup?view=long&pmid=26553211 JAHA.115.002239 - DOI - PMC - PubMed
    1. Dower GE, Yakush A, Nazzal SB, Jutzy RV, Ruiz CE. Deriving the 12-lead electrocardiogram from four (EASI) electrodes. J Electrocardiol. 1988;21 Suppl:S182–7. - PubMed