Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 May 15:197:348-355.
doi: 10.1016/j.talanta.2019.01.045. Epub 2019 Jan 11.

Excitation-emission fluorescence-kinetic third-order/four-way data: Determination of bisphenol A and nonylphenol in food-contact plastics

Affiliations

Excitation-emission fluorescence-kinetic third-order/four-way data: Determination of bisphenol A and nonylphenol in food-contact plastics

Maira D Carabajal et al. Talanta. .

Abstract

The endocrine disrupting chemicals bisphenol A (BPA) and 4-nonylphenol (NP) were simultaneously quantified through third-order/four-way calibration. Excitation-emission fluorescence matrix-kinetic (EEFM-K) third-order data were generated by measuring the EEFMs of these priority xenoestrogens as a function of reaction time during their Fenton degradation. Third-order/four-way calibration notably improves the sensitivity of the method and provides the required selectivity for quantifying analytes with critically overlapped fluorescence signals. In fact, collinearity between BPA and NP emission spectra prevented their quantification using EEFM second-order data and three-way PARAFAC (parallel factor analysis); however, the addition of a third instrumental mode allowed the correct chemometric modeling with four-way PARAFAC. In this way, the compliance of Kruskal's theorem extended to higher-order data was verified. The method was applied for the determination of the analytes in samples of different plastic materials, which are in contact with food and/or beverages. In these cases, where unmodelled constituents are present, good results for BPA were achieved with four-way PARAFAC, but the predictions for NP using this model were deficient. A better predictive capability for NP in real samples was achieved when either U-PLS/RTL (unfolded partial least-squares combined with residual trilinearization) or MCR-ALS (multivariate curve resolution with alternating least-squares) was applied for data processing, demonstrating the power of these latter models for the resolution of more complex systems.

Keywords: 4-Nonylphenol; Bisphenol A; Excitation-emission fluorescence matrix-kinetic data; Multi-way calibration.

PubMed Disclaimer

Similar articles

Cited by

LinkOut - more resources