An Environmental Scan of the National and Provincial Diagnostic Reference Levels in Canada for Common Adult Computed Tomography Scans
- PMID: 30772107
- DOI: 10.1016/j.carj.2018.07.005
An Environmental Scan of the National and Provincial Diagnostic Reference Levels in Canada for Common Adult Computed Tomography Scans
Abstract
Several regulatory bodies have agreed that low-dose radiation used in medical imaging is a weak carcinogen that follows a linear, non-threshold model of cancer risk. While avoiding radiation is the best course of action to mitigate risk, computed tomography (CT) scans are often critical for diagnosis. In addition to the as low as reasonably achievable principle, a more concrete method of dose reduction for common CT imaging exams is the use of a diagnostic reference level (DRL). This paper examines Canada's national DRL values from the recent CT survey and compares it to published provincial DRLs as well as the DRLs in the United Kingdom and the United States of America for the 3 most common CT exams: head, chest, and abdomen/pelvis. Canada compares well on the international scale, but it should consider using more electronic dose monitoring solutions to create a culture of dose optimization.
Keywords: Adult; Computed tomography; Diagnostic reference levels; Radiation monitoring; Standards.
Copyright © 2018 Canadian Association of Radiologists. Published by Elsevier Inc. All rights reserved.
Similar articles
-
Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt.Phys Med. 2017 Jul;39:16-24. doi: 10.1016/j.ejmp.2017.05.050. Epub 2017 Jun 20. Phys Med. 2017. PMID: 28711184
-
Radiation Dose Survey for Common Computed Tomography Exams: 2013 British Columbia Results.Can Assoc Radiol J. 2016 Feb;67(1):88-95. doi: 10.1016/j.carj.2015.07.002. Epub 2015 Nov 19. Can Assoc Radiol J. 2016. PMID: 26608253
-
Updated Australian diagnostic reference levels for adult CT.J Med Radiat Sci. 2020 Mar;67(1):5-15. doi: 10.1002/jmrs.372. Epub 2020 Feb 10. J Med Radiat Sci. 2020. PMID: 32040878 Free PMC article.
-
An Analysis of Computed Tomography Diagnostic Reference Levels in India Compared to Other Countries.Diagnostics (Basel). 2024 Jul 23;14(15):1585. doi: 10.3390/diagnostics14151585. Diagnostics (Basel). 2024. PMID: 39125460 Free PMC article. Review.
-
A Review of Diagnostic Reference Levels in Computed Tomography.Curr Med Imaging. 2022;18(6):623-632. doi: 10.2174/1573405617666210913093839. Curr Med Imaging. 2022. PMID: 34517807 Review.
Cited by
-
Reconstruction of organ doses for patients undergoing computed tomography examinations in Canada 1992-2019.Radiat Prot Dosimetry. 2024 Mar 20;200(4):379-386. doi: 10.1093/rpd/ncad315. Radiat Prot Dosimetry. 2024. PMID: 38186237 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical