. 2019 Feb:131:112-119.
doi: 10.1016/j.radonc.2018.12.007. Epub 2018 Dec 31.

Radiation tolerance of the optic pathway in patients treated with proton and photon radiotherapy

Affiliations

Radiation tolerance of the optic pathway in patients treated with proton and photon radiotherapy

Puyao C Li et al. Radiother Oncol. 2019 Feb.

Abstract

Introduction: Radiation-induced optic neuropathy (RION) is a complication of radiation therapy (RT) that causes blindness. We aimed to define the tolerance of the anterior optic pathway to fractionated RT and identify risk factors for RION.

Materials/methods: Patients with chordoma or chondrosarcoma of the skull base treated with proton and photon therapy between 1983 and 2013, who received a minimum of 30 Gy (relative biologic effectiveness [RBE]) to the anterior optic pathway were assessed. Optic neuropathy with radiographic correlation occurring ≥6 months after completion of RT in the absence of tumor recurrence or other probable cause was diagnosed as RION.

Results: Of 514 patients, 17 developed RION. With median follow-up of 4.8 years, cumulative incidence of RION was 1% among patients receiving <59 Gy (RBE) and 5.8% among patients receiving ≥60 Gy (RBE) to the optic pathway. Higher maximum point dose to the optic pathway (subhazard ratio [SHR] = 1.2, 95% CI 1.05-1.2, p = 0.001), older age (SHR = 1.1, 95% CI 1.02-1.08, p < 0.0005), and female sex (SHR = 16.3, 95% CI 2.2-122.4, p = 0.007) were statistically significant risk factors for RION in multivariate analysis.

Conclusion: In our study cohort, rates of RION were very low with conventionally fractionated RT up to 59 Gy. At doses ≥60 Gy, there is an increased risk of RION, with greater risk for women and older patients.

Keywords: Optic neuropathy; Optic pathway tolerance; Proton therapy; Radiation-induced optic neuropathy.

PubMed Disclaimer

Publication types

MeSH terms