. 2019 Jun;73(6):610-616.
doi: 10.1016/j.annemergmed.2019.01.018. Epub 2019 Feb 14.

Transesophageal Echocardiography During Cardiopulmonary Resuscitation Is Associated With Shorter Compression Pauses Compared With Transthoracic Echocardiography

Affiliations

Transesophageal Echocardiography During Cardiopulmonary Resuscitation Is Associated With Shorter Compression Pauses Compared With Transthoracic Echocardiography

James Fair 3rd et al. Ann Emerg Med. 2019 Jun.

Abstract

Study objective: Point-of-care ultrasonography provides diagnostic information in addition to visual pulse checks during cardiopulmonary resuscitation (CPR). The most commonly used modality, transthoracic echocardiography, has unfortunately been repeatedly associated with prolonged pauses in chest compressions, which correlate with worsened neurologic outcomes. Unlike transthoracic echocardiography, transesophageal echocardiography does not require cessation of compressions for adequate imaging and provides the diagnostic benefit of point-of-care ultrasonography. To assess a benefit of transesophageal echocardiography, we compare the duration of chest compression pauses between transesophageal echocardiography, transthoracic echocardiography, and manual pulse checks on video recordings of cardiac arrest resuscitations.

Methods: We analyzed 139 pulse check CPR pauses among 25 patients during cardiac arrest.

Results: Transesophageal echocardiography provided the shortest mean pulse check duration (9 seconds [95% confidence interval {CI} 5 to 12 seconds]). Mean pulse check duration with transthoracic echocardiography was 19 seconds (95% CI 16 to 22 seconds), and it was 11 seconds (95% CI 8 to 14 seconds) with manual checks. Intraclass correlation coefficient between abstractors for a portion of individual and average times was 0.99 and 0.99, respectively (P<.001 for both).

Conclusion: Our study suggests that pulse check times with transesophageal echocardiography are shorter versus with transthoracic echocardiography for ED point-of-care ultrasonography during cardiac arrest resuscitations, and further emphasizes the need for careful attention to compression pause duration when using transthoracic echocardiography for point-of-care ultrasonography during ED cardiac arrest resuscitations.

PubMed Disclaimer

Conflict of interest statement

Conflict of Interest and Sources of Funding

This study was supported, in part, by the University of Utah Study Design and Biostatistics Center, with funding in part from the National Center for Research Resources and the National Center for Advancing Translational Sciences, National Institutes of Health, through Grant 5UL1TR001067–02 (formerly 8UL1TR000105 and UL1RR025764). None of the funding sources were involved in the design or conduct of the study, collection, management, analysis or interpretation of the data, or preparation, review or approval of the manuscript. None of the authors report any conflicts of interest related to this manuscript.

Figures

Figure 1:
Figure 1:
Overview of total cardiac arrest pauses included for analysis.
Figure 2:
Figure 2:
Bar graph of mean compression pause times comparing palpation alone, TTE use, and TEE use.
Figure 3:
Figure 3:
Dot plot displaying individual pause times within each arrest.

Comment in

References

    1. Link MS, Berkow LC, Kudenchuk PJ, Halperin HR, Hess EP, Moitra VK, et al. Part 7: adult advanced cardiovascular life support: 2015 american heart association guidelines update for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation 2015;132(18 Suppl 2):S444–64 November 3. - PubMed
    1. Soar J, Nolan JP, Böttiger BW, Perkins GD, Lott C, Carli P, et al. European resuscitation council guidelines for resuscitation 2015 section 3. adult advanced life support. Resuscitation 2015;95:100–47. - PubMed
    1. Berg RA, Sanders AB, Kern KB, et al. Adverse hemodynamic effects of interrupting chest compressions for rescue breathing during cardiopulmonary resuscitation for ventricular fibrillation cardiac arrest. Circulation. 2001;104(20):2465–2470. - PubMed
    1. Christenson J, Andrusiek D, Everson-Stewart S, et al. Chest Compression Fraction Determines Survival in Patients with Out-of-hospital Ventricular Fibrillation. Circulation 2009. September 29; 120(13): 1241–1247 - PMC - PubMed
    1. Gaspari R et al. Emergency Department Point-Of-Care Ultrasound in Out-Of-Hospital and in-ED Cardiac Arrest. Resuscitation 2016; 109: 33–39 - PubMed

Publication types