Abstract

Background: Parkinsonian rigidity is identified on clinical examination as resistance to passive movement. Measurement of rigidity commonly relies on ordinal rating scales (MDS-UPDRS), however instrumented objective measures may provide greater mechanistic insight.

New method: We present a palm-worn instrument to objectively quantify rigidity on a continuous scale. The device employs a miniature motor to flex the third digit of the hand about the metacarpophalangeal joint whilst transducers record flexion/extension forces. We aim to determine congruence with the MDS-UPDRS, investigate sensitivity to the impact of deep brain stimulation (DBS) and contralateral movement, and make comparisons with healthy individuals. Eight participants with Parkinson's disease underwent evaluation during conditions: on and off DBS, and with and without contralateral limb movement to activate rigidity. During each DBS condition, wash-in/out effects were tracked using both our instrument and two blinded clinical raters. Sixteen healthy volunteers (age-matched/young) served as controls.

Results: Rigidity measured using our instrument had moderate agreement with the MDS-UPDRS and showed differences between therapeutic state, activation conditions, and disease/healthy cohorts. Rigidity gradually worsened over a one-hour period after DBS cessation, but improved more rapidly with DBS resumption.

Comparison with existing methods: Previous attempts to quantify rigidity include manual approaches where a clinician is required to manipulate limbs while sensors passively gather information, or large automated instruments to move the wrist or elbow.

Conclusion: Given its ability to track changes in rigidity due to therapeutic intervention, our technique could have applications where continuous measurement is required or where a suitably qualified rater is absent.

Keywords: Movement disorders; Objective monitoring; Parkinson’s disease; Rigidity; Stiffness.