The Accommodation of Bone Anchors Within the Distal Phalanx for Repair of Flexor Digitorum Profundus Avulsions
- PMID: 30777399
- DOI: 10.1016/j.jhsa.2018.12.012
The Accommodation of Bone Anchors Within the Distal Phalanx for Repair of Flexor Digitorum Profundus Avulsions
Abstract
Purpose: Avulsion injury of the flexor digitorum profundus (FDP) tendon has been traditionally repaired with a pull-out suture over the nail plate. Complication rates with this method and improvements in anchor design have led to the increased use of bone anchors to give a rigid all-inside repair. However, the dimensions of the distal phalanx may limit their use. The primary hypothesis was that 2 micro bone anchors could fit in either perpendicular or 45° proximally angled positions within each distal phalanx. A further hypothesis was that 1 mini bone anchor could fit in similar positions in the distal phalanx.
Methods: Thirty-two fresh frozen fingers were dissected, and the FDP tendon was removed from the distal phalanx footprint. Two bone anchor types were used, mini and micro sizes, and inserted at 2 angles, perpendicular and 45° proximally angled. Observations of dorsal cortex and joint space penetration were recorded. Distal phalanx dimensions were measured for each finger.
Results: The micro anchors penetrated the dorsal cortex in perpendicular tests in little fingers only. The micro anchor did not penetrate the joint in any angled tests. The mini bone anchor penetrated the dorsal cortex in 100% of perpendicular tests and the joint in 63% of angled tests, although none of these included the middle finger.
Conclusions: Two micro bone anchors fit within the distal phalanx in all fingers tested, except the little finger, when placed in the perpendicular position. At a 45° angle, the distal phalanx of the little finger can also accommodate micro bone anchors without any evidence of complication when placed 4 mm from the joint. The mini anchors were too large to fit in a perpendicular position within the distal phalanx. In the 45° angled position, the joint was not penetrated by the mini anchor in only middle fingers.
Clinical relevance: The study provides anatomical evidence of the accommodation of micro bone anchors within the distal phalanx in perpendicular or 45° angled positions for the repair of FDP tendon avulsion injury.
Keywords: Bone anchor; flexor digitorum profundus; repair; tendon avulsion.
Copyright © 2019 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.
Similar articles
-
The Effect of Distal Phalanx Bony Dimensions in Suture Anchor Fixations of Tendon Avulsion.J Hand Surg Asian Pac Vol. 2018 Sep;23(3):347-350. doi: 10.1142/S2424835518500340. J Hand Surg Asian Pac Vol. 2018. PMID: 30282538
-
Repair Technique Using a Combination of Suture Anchor and Miniscrew in Flexor Digitorum Profundus Bony Avulsion Fracture with Bone Fragment in Zone 1.J Hand Surg Asian Pac Vol. 2018 Sep;23(3):430-436. doi: 10.1142/S242483551872030X. J Hand Surg Asian Pac Vol. 2018. PMID: 30282548
-
Intramedullary Suture Anchor Fixation of a Type Vb Flexor Digitorum Profundus Avulsion: A Case Report.JBJS Case Connect. 2021 Jul 15;11(3). doi: 10.2106/JBJS.CC.21.00044. JBJS Case Connect. 2021. PMID: 34264876
-
Zone I Flexor Digitorum Profundus Repair: A Surgical Technique.J Hand Surg Am. 2019 Feb;44(2):164.e1-164.e5. doi: 10.1016/j.jhsa.2018.08.015. Epub 2018 Oct 8. J Hand Surg Am. 2019. PMID: 30309664 Review.
-
Avulsion injuries of the flexor digitorum profundus tendon.J Am Acad Orthop Surg. 2011 Mar;19(3):152-62. doi: 10.5435/00124635-201103000-00004. J Am Acad Orthop Surg. 2011. PMID: 21368096 Review.
Cited by
-
A suture anchor-based repair technique for type IV jersey finger injuries: a biomechanical investigation.Sci Rep. 2023 Mar 1;13(1):3493. doi: 10.1038/s41598-023-30373-w. Sci Rep. 2023. PMID: 36859502 Free PMC article.
-
Anatomy and histomorphology of the flexor digitorum profundus enthesis: functional implications for tissue engineering and surgery.BMC Musculoskelet Disord. 2021 Dec 10;22(1):1032. doi: 10.1186/s12891-021-04922-1. BMC Musculoskelet Disord. 2021. PMID: 34893040 Free PMC article.
-
An unusual late complication of mitek suture anchor use 10 years after primary repair of a flexor digitorum profundus tendon laceration: a case report and literature review.Case Reports Plast Surg Hand Surg. 2025 Mar 6;12(1):2473373. doi: 10.1080/23320885.2025.2473373. eCollection 2025. Case Reports Plast Surg Hand Surg. 2025. PMID: 40065778 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical