Aniseikonia and anisometropia: implications for suppression and amblyopia
- PMID: 30791133
- DOI: 10.1111/cxo.12881
Aniseikonia and anisometropia: implications for suppression and amblyopia
Abstract
Aniseikonia is a difference in the perceived size or shape of images between eyes, and can arise from a variety of physiological, neurological, retinal, and optical causes. Aniseikonia is associated with anisometropia, as both anisometropia itself and the optical correction for anisometropia can cause aniseikonia. Image size differences above one to three per cent can be clinically symptomatic. Common symptoms include asthenopia, headache and diplopia in vertical gaze. Size differences of three and more impair binocular visual functions such as binocular summation and stereopsis. Above five per cent of aniseikonia, binocular inhibition or suppression tend to occur to prevent diplopia and confusion. Aniseikonia can be measured using a range of techniques and can be corrected or reduced by prescribing contact lenses or specially designed spectacle lenses. Subjective testing of aniseikonia is the only way to accurately measure the overall perceived amount of aniseikonia. However, currently it is not routinely assessed in most clinical settings. At least two-thirds of patients with amblyopia have anisometropia, thus we may expect aniseikonia to be common in patients with anisometropic amblyopia. However, aniseikonia may not be experienced by the patient under normal binocular viewing conditions if the image from the amblyopic eye is of poor quality or is too strongly suppressed for image size differences to be recognised. This lack of binocular simultaneous perception in amblyopia may also prevent the measurement of aniseikonia, as most common techniques require direct comparisons of images seen by each eye. Current guidelines for the treatment of amblyopia advocate full correction of anisometropia to equalise image clarity, but do not address aniseikonia. Significant image size differences between eyes may lead to suppression and abnormal binocular adaptations. It is possible that correcting anisometropia and aniseikonia simultaneously, particularly at the initial diagnosis of anisometropia, would reduce the need to develop suppression and improve treatment outcomes for anisometropic amblyopia.
Keywords: amblyopia; aniseikonia; anisometropia; suppression.
© 2019 Optometry Australia.
Similar articles
-
Measuring aniseikonia and investigating neuroplasticity and image factors in amblyopia (MAGNIFY): study protocol for a randomised clinical trial.Trials. 2022 Apr 27;23(1):358. doi: 10.1186/s13063-022-06159-2. Trials. 2022. PMID: 35478070 Free PMC article.
-
Aniseikonia.2023 Aug 8. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2023 Aug 8. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 36256755 Free Books & Documents.
-
Reduced aniseikonia in axial anisometropia with contact lens correction.Ophthalmic Physiol Opt. 1988;8(3):341-4. Ophthalmic Physiol Opt. 1988. PMID: 3077649
-
Orthoptic indications for contact lens wear.Cont Lens Anterior Eye. 2006 Sep;29(4):175-81; quiz 211. doi: 10.1016/j.clae.2006.03.007. Epub 2006 May 18. Cont Lens Anterior Eye. 2006. PMID: 16713327 Review.
-
[Features of the electronic eikonometer for the study of binocular function].J Fr Ophtalmol. 2013 May;36(5):418-30. doi: 10.1016/j.jfo.2012.09.008. Epub 2013 Mar 30. J Fr Ophtalmol. 2013. PMID: 23545337 Review. French.
Cited by
-
Measuring aniseikonia and investigating neuroplasticity and image factors in amblyopia (MAGNIFY): study protocol for a randomised clinical trial.Trials. 2022 Apr 27;23(1):358. doi: 10.1186/s13063-022-06159-2. Trials. 2022. PMID: 35478070 Free PMC article.
-
A case of reverse amblyopia in a myopic anisometropic patient: an atypical presentation.J Surg Case Rep. 2024 May 23;2024(5):rjae320. doi: 10.1093/jscr/rjae320. eCollection 2024 May. J Surg Case Rep. 2024. PMID: 38784199 Free PMC article.
-
Opinions on Amblyopia Treatment in Microtropia - A Questionnaire Study of Orthoptists in Scandinavia.Br Ir Orthopt J. 2024 Nov 13;20(1):226-234. doi: 10.22599/bioj.316. eCollection 2024. Br Ir Orthopt J. 2024. PMID: 39552717 Free PMC article.
-
The Modulation of Laser Refractive Surgery on Sensory Eye Dominance of Anisometropia.J Ophthalmol. 2020 Mar 27;2020:3873740. doi: 10.1155/2020/3873740. eCollection 2020. J Ophthalmol. 2020. PMID: 32351721 Free PMC article.
-
Assessment of the effects of induced anisometropia on binocularity with glasses-free 3D technique.Int J Ophthalmol. 2023 Apr 18;16(4):601-607. doi: 10.18240/ijo.2023.04.14. eCollection 2023. Int J Ophthalmol. 2023. PMID: 37077487 Free PMC article.
References
REFERENCES
-
- Donders F. On the Anomalies of Accommodation and Refraction of the Eye. London: New Sydenham Society, 1864.
-
- Ames A. Aniseikonia-a factor in the functioning of vision. Am J Ophthalmol 1935; 18: 1014-1020.
-
- Lancaster WB. Aniseikonia. Trans Am Ophthalmol Soc 1938; 36: 227-234.
-
- Rutstein RP, Corliss DA, Fullard RJ. Comparison of aniseikonia as measured by the aniseikonia inspector and the space eikonometer. Optom Vis Sci 2006; 83: 836-842.
-
- Langenbucher AS. Anisometropia and aniseikonia--unsolved problems of cataract surgery. Klin Monbl Augenheilkd 2008; 225: 763-769.