Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Randomized Controlled Trial
. 2019 Jun 1;21(6):900-908.
doi: 10.1093/europace/euz018.

The impact of implantable cardioverter-defibrillator implantation on health-related quality of life in the DANISH trial

Affiliations
Randomized Controlled Trial

The impact of implantable cardioverter-defibrillator implantation on health-related quality of life in the DANISH trial

Johan S Bundgaard et al. Europace. .

Abstract

Aim: The Danish Study to Assess the Efficacy of Implantable Cardioverter-Defibrillators (ICD) in Patients with Non-ischaemic Systolic Heart Failure (HF) on Mortality (DANISH) found no overall effect on all-cause mortality. The effect of ICD implantation on health-related quality of life (HRQoL) remains to be established as previous trials have demonstrated conflicting results. We investigated the impact of ICD implantation on HRQoL in patients with non-ischaemic systolic HF, a prespecified secondary endpoint in DANISH.

Methods and results: In DANISH, a total of 1116 patients with non-ischaemic systolic HF were randomly assigned (1:1) to ICD implantation or usual clinical care (control). Patients completed disease-specific HRQoL as assessed by Minnesota Living with Heart Failure Questionnaire (MLHFQ; 0-105, high indicating worse). Changes in HRQoL 8 months after randomization were assessed with a mixed-effects model. At randomization, MLHFQ was completed by 935 (84%) patients (n = 472 in the ICD group and n = 463 in the control group) and was reassessed in 274 (58%) and 292 (63%) patients, respectively after 8 months for the primary analysis. Patients in the ICD group vs. the control group had similar improvements in MLHFQ after 8 months [least square mean -7.0 vs. -4.2 (P = 0.13)]. A clinically relevant improvement (decrease ≥5) in the MLHFQ overall score at 8 months was observed in 151 patients in the ICD group and 148 patients in the control group [55% vs. 51%, respectively (P = 0.25)].

Conclusion: Implantable cardioverter-defibrillator implantation in patients with non-ischaemic systolic HF did not significantly alter HRQoL compared with patients randomized to usual clinical care.

Keywords: Cardiovascular disease; Heart failure; Implantable cardioverter-defibrillator; Quality of life.

PubMed Disclaimer

Publication types