Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Case Reports
. 2019 May;23(3):e13362.
doi: 10.1111/petr.13362. Epub 2019 Feb 22.

First report of successful transplantation of a pediatric donor liver graft after hypothermic machine perfusion

Affiliations
Case Reports

First report of successful transplantation of a pediatric donor liver graft after hypothermic machine perfusion

Maureen J M Werner et al. Pediatr Transplant. 2019 May.

Abstract

One of the main limiting factors in pediatric liver transplantation is donor availability. For adults, DCD liver grafts are increasingly used to expand the donor pool. To improve outcome after DCD liver transplantation, ex situ machine perfusion is used as an alternative organ preservation strategy, with the supplemental value of providing oxygen to the graft during preservation. We here report the first successful transplantation of a pediatric DCD liver graft after hypothermic oxygenated machine perfusion. The full-size liver graft was derived from a 13-year-old, female DCD donor and was end-ischemic pretreated with dual hypothermic oxygenated machine perfusion. Arterial and portal pressures were set at 18 and 4 mm Hg, slightly lower than protocolized settings for adult livers. During 2 hours of machine perfusion, portal and arterial flows increased from 100 to 210 mL/min and 30 to 63 mL/min, respectively. The pretreated liver graft was implanted in a 16-year-old girl with progressive familial intrahepatic cholestasis type 2. Postoperative AST, ALT, and prothrombin time normalized within a week. The recipient quickly recovered and was discharged from the hospital after 18 days. One year after transplantation, she is in excellent condition with a completely normal liver function and histology. This case is the first report of successful transplantation of a pediatric DCD liver graft after hypothermic oxygenated machine perfusion and illustrates the potential role of ex situ machine perfusion in expanding the donor pool and improving outcome after pediatric liver transplantation.

Keywords: donation after circulatory death; hypothermic oxygenated machine perfusion; pediatric liver transplantation.

PubMed Disclaimer

Publication types

LinkOut - more resources