Black Diaphragm Intraocular Lens Implantation in Patients with Aniridia
- PMID: 30820283
- PMCID: PMC6388531
- DOI: 10.4103/jovr.jovr_244_17
Black Diaphragm Intraocular Lens Implantation in Patients with Aniridia
Abstract
Purpose: To review the management outcomes of black diaphragm intraocular (BDI) lens implantation in Arab patients with aniridia.
Methods: Patients with aniridia undergone BDI lens implantation at our institution between 2013 and 2014 were included. Uncorrected visual acuity (UCVA), manifest refraction, and best-corrected visual acuity (BCVA) were evaluated before and 6 months and yearly after BDI lens implant surgery until the last visit. Intra- and postoperative complications were noted.
Results: Our series comprised 14 patients (8 males) with aniridia. The median duration of follow-up was 30 months (25% quartile). Ocular parameters, refractive status, and vison were all significantly improved at the last follow-up compared to the preoperative values (P < 0.05 for all comparisons). All patients reported a significant decrease in photophobia and glare. Postoperatively, 11 eyes (78%) gained 2 or more lines of UCVA. At the last follow-up, BCVA increased by 2 or more lines in all cases. Early postoperative complications included main wound leakage (one eye) and anterior chamber hyphema (one eye). Late (≥6 months) complications included corneal decompensation (one eye), failed penetrating keratoplasty graft (2 eyes), and subluxation of a scleral fixated BDI lens (one eye). Surgical interventions performed to manage complications included penetrating keratoplasty in 2 eyes with corneal decompensation and failed graft (one each), and re-suturing of a subluxated intraocular lens (one eye).
Conclusion: BDI lenses seem to be a safe and effective iris prosthetic with intraocular lens combination surgery for patients with congenital or traumatic aniridia. Periodic evaluation and prompt management of complications are recommended.
Keywords: Aniridia; Black Diaphragm Intraocular Lens Implantation; Visual Disturbances.
Conflict of interest statement
There are no conflicts of interest.
References
-
- Nelson LB, Spaeth GL, Nowinski TS, Margo CE, Jackson L. Aniridia. A review. Surv Ophthalmol. 1984;28:621–642. - PubMed
-
- Weissbart SB, Ayres BD. Management of aniridia and iris defects: An update on iris prosthesis options. Curr Opin Ophthalmol. 2016;27:244–249. - PubMed
-
- Srinivasan S, Ting DS, Snyder ME, Prasad S, Koch HR. Prosthetic iris devices. Can J Ophthalmol. 2014;49:6–17. - PubMed
-
- Reinhard T, Engelhardt S, Sundmacher R. Black diaphragm aniridia intraocular lens for congenital aniridia: Long-term follow-up. J Cataract Refract Surg. 2000;26:375–381. - PubMed
-
- Aslam SA, Wong SC, Ficker LA, MacLaren RE. Implantation of the black diaphragm intraocular lens in congenital and traumatic aniridia. Ophthalmology. 2008;115:1705–1712. - PubMed
LinkOut - more resources