Direct Analysis of Aqueous Solutions and Untreated Biological Samples Using Nanoelectrospray Ionization Mass Spectrometry with Pipette Tip in Series with High-Ohmic Resistor as Ion Source

Affiliations

Direct Analysis of Aqueous Solutions and Untreated Biological Samples Using Nanoelectrospray Ionization Mass Spectrometry with Pipette Tip in Series with High-Ohmic Resistor as Ion Source

Matiur Rahman et al. J Am Soc Mass Spectrom. 2019 May.

Erratum in

Abstract

Commercially available disposable plastic pipette tip with the inner diameter of ca. 120 μm in series with a high-ohmic resistor (10 GΩ) was adapted as a low-cost alternative ion source for high-throughput nanoelectrospray mass spectrometry (nESI-MS) analysis of a variety of samples, especially aqueous solutions, without sample pretreatment. The use of high-ohmic resistor enabled the formation of stable electrospray of aqueous solutions at ambient conditions. In addition, corona discharge was avoided even with a high voltage applied. Quantitative analysis of vitamin B in water was successfully conducted by tip-ESI. The results exhibited a good linearity (R ˃ 0.9983), a low detection limit (0.25 ng/mL), and a wide dynamic response range (0.25-1000 ng/mL). Our study revealed that tip-ESI not only performed equally well to capillary nESI in terms of flow rate (˂ 100 nL/min), signal sensitivity, and sample consumption, but also offered a number of additional advantages, including better signal duration, tolerance to high analyte concentration (> 100 μg/mL) and high ionizing voltage (up to 6 kV), and obviation of tip clogging and corona discharge. High compatibility of tip-ESI with various kinds of samples (aqueous, viscous, solid, or bulk biological samples) makes it a promising tool for direct MS analysis.

Keywords: Aqueous solution; Clogging; Direct analysis; Pipette tip; Resistor.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Rapid Commun Mass Spectrom. 2010 Dec 15;24(23):3425-31 - PubMed
    1. Angew Chem Int Ed Engl. 2007;46(4):580-3 - PubMed
    1. Anal Chem. 2010 Mar 15;82(6):2463-71 - PubMed
    1. J Mass Spectrom. 2007 Jan;42(1):58-69 - PubMed
    1. Nat Protoc. 2015 Sep;10(9):1445-56 - PubMed

LinkOut - more resources