Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2019 Jun;26(3):302-311.
doi: 10.1177/1553350619833291. Epub 2019 Mar 5.

Non-Cross-Linked Collagen Mesh Performs Best in a Physiologic, Noncontaminated Rat Model

Affiliations

Non-Cross-Linked Collagen Mesh Performs Best in a Physiologic, Noncontaminated Rat Model

Ruth Kaufmann et al. Surg Innov. 2019 Jun.

Abstract

Background: In laparoscopic incisional hernia repair, direct contact between the prosthesis and abdominal viscera is inevitable and may lead to adhesions. Despite the large variety of mesh prosthesis, little is known about their in vivo behavior. Biological meshes are considered to have many advantages, but due to their price they are rarely used. A rat model was used to assess biological and conventional synthetic meshes on their in vivo characteristics.

Design: One-hundred twenty male Wistar rats were randomized into five groups of 24 rats. A mesh was implanted intraperitoneally and fixated with nonresorbable sutures. The following five meshes were implanted: Parietene (polypropylene), Permacol (cross-linked porcine acellular dermal matrix), Strattice (non-cross-linked porcine acellular dermal matrix), XCM Biologic (non-cross-linked porcine acellular dermal matrix), and Omyra Mesh (condensed polytetrafluoroethylene). The rats were sacrificed after 30, 90, or 180 days. Incorporation, shrinkage, adhesions, abscess formation, and histology were assessed for all meshes.

Results: All animals thrived postoperatively. After 180 days, Permacol, Parietene, and Omyra Mesh had a significantly better incorporation than Strattice ( P = .001, P = .019, and P = .037 respectively). After 180 days, Strattice had significantly fewer adhesions on the surface of the mesh than Parietene ( P < .001), Omyra Mesh ( P = .011), and Permacol ( P = .027). After 30 days, Permacol had significantly stronger adhesions than Strattice ( P = .030). However, this difference was not significant anymore after 180 days. After 180 days, there was significantly less shrinkage in Permacol than in Strattice ( P = .001) and Omyra Mesh ( P = .050).

Conclusion: Based on incorporation, adhesions, mesh shrinkage, and histologic parameters, Strattice performed best in this experimental rat model.

Keywords: biological mesh; incisional hernia; intraperitoneal mesh; rat model; synthetic mesh.

PubMed Disclaimer

Conflict of interest statement

Declaration of Conflicting Interests: The author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Figures

Figure 1.
Figure 1.
Photograph taken at time of sacrifice showing inner abdominal wall and mesh site (non-cross-linked biological mesh). The black box is a schematic representation of tissue sampling for histopathology.
Figure 2.
Figure 2.
Mean percentage incorporation of each mesh at 30, 90, and 180 days.
Figure 3.
Figure 3.
Median shrinkage of each mesh at 30, 90, and 180 days.
Figure 4.
Figure 4.
Median percentage of adhesions on each mesh at 30, 90, and 180 days.

Similar articles

Cited by

References

    1. Van Ramshorst GH, Eker HH, Hop WC, Jeekel J, Lange JF. Impact of incisional hernia on health-related quality of life and body image: a prospective cohort study. Am J Surg. 2012;204:144-150. - PubMed
    1. Luijendijk RW, Hop WC, van den Tol MP, et al. A comparison of suture repair with mesh repair for incisional hernia. N Engl J Med. 2000;343:392-398. - PubMed
    1. Burger JW, Luijendijk RW, Hop WC, Halm JA, Verdaasdonk EG, Jeekel J. Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia. Ann Surg. 2004;240:578-585. - PMC - PubMed
    1. Cevasco M, Itani KM. Ventral hernia repair with synthetic, composite, and biologic mesh: characteristics, indications, and infection profile. Surg Infect (Larchmt). 2012;13:209-215. - PubMed
    1. Cobb WS, Kercher KW, Heniford BT. Laparoscopic repair of incisional hernias. Surg Clin North Am. 2005;85:91-103. - PubMed