Inter-observer variability of clinical target volume delineation in definitive radiotherapy of neck lymph node metastases from unknown primary. A cooperative study of the Italian Association of Radiotherapy and Clinical Oncology (AIRO) Head and Neck Group
- PMID: 30852793
- DOI: 10.1007/s11547-019-01006-y
Inter-observer variability of clinical target volume delineation in definitive radiotherapy of neck lymph node metastases from unknown primary. A cooperative study of the Italian Association of Radiotherapy and Clinical Oncology (AIRO) Head and Neck Group
Abstract
Background: This study, promoted by Italian Association of Radiotherapy and Clinical Oncology (AIRO) Head and Neck Group, aimed to assess the current national practice of target volume delineation on a case of neck lymph node metastases from unknown primary evaluating inter-observer variability, in a setting of primary radiotherapy.
Materials and methods: A case of metastatic neck lymph node from occult primary was proposed to 17 radiation oncologists. A national reference RT center was identified and considered as benchmark. Participants were requested to delineate target volumes. A structured questionnaire was administered. A comparison between following parameters of the CTVs was performed: centroids distances, Dice similarity index (DSI), Jaccard index and mean distance to agreement (MDA). Volume expressed in cubic centimeters and CTVs cranio-caudal extension were evaluated.
Results: Sixteen of 17 radiation oncologists recommended three CTVs dose levels. (CTV HD, CTV ID and CTV LD); CTV ID was not delineated by one of the participants and by the reference center. The distance between the reference centroid and the mean centroid of CTVs HD was 1.09 cm (0.36-3.99 cm); for CTV LD, a mean centroids distance of 2.45 (0.27-4.83 cm) was found, and for CTV HD, mean DSI is 0.48 and mean Jaccard index is 0.32 and MDA was 8.89 mm. CTV LD showed a mean DSI of 0.46, mean Jaccard index of 0.31 and MDA of 14.87 when compared to the reference.
Conclusion: Many aspects concerning treatment optimization of cervical nodes metastases from occult primary remain unclear, and we found a notable heterogeneity of global radiotherapy management reporting discordances both in target volume delineation and volume prescription.
Keywords: Head and neck cancer; Inter-observer variability; Neck lymph node metastases; Radiotherapy; Target volume delineation; Unknown primary.
Similar articles
-
Inter-observer variability of clinical target volume delineation in radiotherapy treatment of pancreatic cancer: a multi-institutional contouring experience.Radiat Oncol. 2014 Sep 8;9:198. doi: 10.1186/1748-717X-9-198. Radiat Oncol. 2014. PMID: 25199768 Free PMC article.
-
Dedicated MRI simulation for cervical cancer radiation treatment planning: Assessing the impact on clinical target volume delineation.J Med Imaging Radiat Oncol. 2019 Apr;63(2):236-243. doi: 10.1111/1754-9485.12831. Epub 2018 Dec 3. J Med Imaging Radiat Oncol. 2019. PMID: 30506944
-
Delineation of the primary tumour Clinical Target Volumes (CTV-P) in laryngeal, hypopharyngeal, oropharyngeal and oral cavity squamous cell carcinoma: AIRO, CACA, DAHANCA, EORTC, GEORCC, GORTEC, HKNPCSG, HNCIG, IAG-KHT, LPRHHT, NCIC CTG, NCRI, NRG Oncology, PHNS, SBRT, SOMERA, SRO, SSHNO, TROG consensus guidelines.Radiother Oncol. 2018 Jan;126(1):3-24. doi: 10.1016/j.radonc.2017.10.016. Epub 2017 Nov 24. Radiother Oncol. 2018. PMID: 29180076
-
Positron emission tomography for radiation treatment planning.Strahlenther Onkol. 2005 Aug;181(8):483-99. doi: 10.1007/s00066-005-1422-7. Strahlenther Onkol. 2005. PMID: 16044216 Review.
-
Radiation-induced hypothyroidism after treatment of head and neck cancer.Dan Med J. 2016 Mar;63(3):B5213. Dan Med J. 2016. PMID: 26931197 Review.
Cited by
-
Head and neck automatic multi-organ segmentation on Dual-Energy Computed Tomography.Phys Imaging Radiat Oncol. 2024 Sep 30;32:100654. doi: 10.1016/j.phro.2024.100654. eCollection 2024 Oct. Phys Imaging Radiat Oncol. 2024. PMID: 39803347 Free PMC article.
-
Apparent diffusion coefficient magnetic resonance imaging (ADC-MRI) in the axillary breast cancer lymph node metastasis detection: a narrative review.Gland Surg. 2020 Dec;9(6):2225-2234. doi: 10.21037/gs-20-546. Gland Surg. 2020. PMID: 33447575 Free PMC article. Review.
-
Interobserver Variability in a Spanish Society of Radiation Oncology (SEOR) Head and Neck Course. Is Current Contouring Training Sufficient?Adv Radiat Oncol. 2024 Aug 10;9(11):101591. doi: 10.1016/j.adro.2024.101591. eCollection 2024 Nov. Adv Radiat Oncol. 2024. PMID: 39493292 Free PMC article.
-
Interobserver variability studies in diagnostic imaging: a methodological systematic review.Br J Radiol. 2023 Aug;96(1148):20220972. doi: 10.1259/bjr.20220972. Epub 2023 Jun 29. Br J Radiol. 2023. PMID: 37399082 Free PMC article.
-
Is an all-phase ITV (internal target volume) a gold standard in the target definition of hepatocellular carcinoma?J Appl Clin Med Phys. 2024 Dec;25(12):e14532. doi: 10.1002/acm2.14532. Epub 2024 Sep 16. J Appl Clin Med Phys. 2024. PMID: 39284228 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical
Research Materials