Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2018 Jun 15:627:1404-1432.
doi: 10.1016/j.scitotenv.2018.01.277. Epub 2018 Feb 20.

Micropollutants in drinking water from source to tap - Method development and application of a multiresidue screening method

Affiliations
Free article

Micropollutants in drinking water from source to tap - Method development and application of a multiresidue screening method

Rikard Tröger et al. Sci Total Environ. .
Free article

Abstract

A multi-residue screening method for simultaneous measurement of a wide range of micropollutants in drinking water (DW) resources was developed. The method was applied in a field study in central Sweden on water from source to tap, including samples of surface water (upstream and downstream of a wastewater treatment plant, WWTP), intake water before and after a DW treatment plant (DWTP, pilot and full-scale), treated DW leaving the plant and tap water at end users. Low detection limits (low ng L-1 levels) were achieved by using large sample volumes (5 L) combined with ultra performance liquid chromatography high resolution mass spectrometry (UPLC-HRMS). In total, 134 different micropollutants were analyzed, including pesticides, pharmaceuticals and personal care products (PPCPs), drug-related compounds, food additives, and perfluoroalkyl substances (PFASs). Of these 134 micropollutants, 41 were detected in at least one sample, with individual concentrations ranging from sub ng L-1 levels to ~80 ng L-1. Two solid phase extraction (SPE) cartridges (Oasis HLB and Bond-Elut ENV) were shown to be complementary in the field study, with three compounds detected exclusively using HLB. The total concentration in treated drinking water (56-57 ng L-1) was at a similar level as upstream from the WWTP (79-90 ng L-1). The composition of micropollutants changed along the water path, to a higher fraction of food additives and PFASs. Median treatment efficiency in the full-scale DWTP was close to 0%, but with high variability for individual compounds. In contrast, median treatment efficiency in the pilot-scale DWTP was ~90% when using nanofiltration followed by a freshly installed granulated active carbon (GAC) filter.

Keywords: Drinking water; Mass spectrometry; Micropollutants; Multiresidue method; Water treatment.

PubMed Disclaimer

LinkOut - more resources