Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2019 Mar 12;19(1):81.
doi: 10.1186/s12909-019-1512-3.

Students' perspectives on the use of digital versus conventional dental impression techniques in orthodontics

Affiliations
Comparative Study

Students' perspectives on the use of digital versus conventional dental impression techniques in orthodontics

Timm C Schott et al. BMC Med Educ. .

Abstract

Background: Despite the increasing use of digital impressions in orthodontics, this technique does not usually form part of the learning objectives in dental training. The aim of this study was to determine how students assess the user-friendliness of intraoral scanners compared to a conventional impression technique after a theoretical and practical teaching module.

Methods: Thirty-one dental students in their seventh semester (4th year) received and conducted digital (3 M, St. Paul, NM) and conventional (alginate) impressions from: (i) the dentist's perspective, and (ii) the patient's perspective. Each student completed four questionnaires to evaluate: (i) the user-friendliness of intraoral scanning, and (ii) intraoral scanning compared to the conventional method.

Results: Thirty (97%) students had not previously performed digital impressions. Twenty-four (77%) students were overall "very" or "rather" satisfied with the handling of the intraoral scanning method, and 18 (58%) preferred digital to alginate impressions from the dentist's perspective. From the "patient's" perspective, the students did not report any significant differences between the two methods. However, the impression tray in conventional impressions reduced "patient" comfort significantly more than the camera in digital impressions (Z = - 3.496, p < 0.001).

Conclusions: Dental students were able to practice both conventional alginate and modern digital impressions without prior knowledge of intraoral impression techniques after basic training and an introduction from dentists. Students reported a preference for the digital technique. Implementing digital intraoral impressions into undergraduate training is recommended to familiarise students with this rapidly developing digital technique at an early stage.

Keywords: Alginate impressions; Dental student; Digital impressions; Intraoral scanner; Training.

PubMed Disclaimer

Conflict of interest statement

Ethics approval and consent to participate

Ethical approval was sought and approved from the University of Tübingen Ethics Committee (466/2016BO2). Written informed consent was obtained from all participants.

Consent for publication

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Similar articles

Cited by

References

    1. Caputi S, Varvara G. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study. J Prosthet Dent. 2008;99(4):274–281. doi: 10.1016/S0022-3913(08)60061-X. - DOI - PubMed
    1. Hamalian TA, Nasr E, Chidiac JJ. Impression materials in fixed prosthodontics: influence of choice on clinical procedure. J Prosthodont. 2011;20(2):153–160. doi: 10.1111/j.1532-849X.2010.00673.x. - DOI - PubMed
    1. Nissan J, Laufer BZ, Brosh T, Assif D. Accuracy of three polyvinyl siloxane putty-wash impression techniques. J Prosthet Dent. 2000;83(2):161–165. doi: 10.1016/S0022-3913(00)80007-4. - DOI - PubMed
    1. Noack T, Balkenhol M, Ferger P, Wöstmann B. Klinisch erreichbare Abformgenauigkeit von A-Silikonen. Dtsch Zahnarztl Z. 2004;59:590–592.
    1. Siemer A, Balkenhol M, Trost M, Ferger P, Wöstmann B. Abformgenauigkeit von Doppelmischabformungen vs. Korrekturabformungen - eine 3D-Scan In-vitro- Studie. Dtsch Zahnarztl Z. 2004;59:585–589.

Publication types