Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Observational Study
. 2020 Feb;13(2 Pt 1):345-353.
doi: 10.1016/j.jcmg.2019.01.027. Epub 2019 Mar 13.

Determinants of Bioprosthetic Aortic Valve Degeneration

Affiliations
Free article
Observational Study

Determinants of Bioprosthetic Aortic Valve Degeneration

Christian Nitsche et al. JACC Cardiovasc Imaging. 2020 Feb.
Free article

Abstract

Objectives: The aim of the present long-term study was to assess the incidence and mode of valve hemodynamic deterioration (VHD) of bioprosthetic aortic valves, as well as associated factors.

Background: Modern definitions of bioprosthetic valve deterioration recommend the use of echocardiography for the assessment of transprosthetic gradients and valvular regurgitation.

Methods: A total of 466 consecutive patients (mean age 73.5 ± 7.5 years, 56.0% women) underwent surgical bioprosthetic aortic valve replacement between 1994 and 2014. Clinical assessment, transthoracic echocardiography, and laboratory testing were performed at baseline and follow-up. VHD was defined as mean transprosthetic gradient ≥30 mm Hg and/or at least moderate valvular regurgitation on echocardiography. Patient-prosthesis mismatch was defined as an effective orifice area indexed to body surface area ≤0.8 cm2/m2.

Results: Patients were followed for a median of 112.3 months (interquartile range: 57.7 to 147.7 months). Among patients with complete follow-up (n = 383), 70 subjects (18.3%; 4.8% per valve-year) developed VHD after a median of 32.4 months (interquartile range: 12.9 to 87.2 months; stenosis, n = 45; regurgitation, n = 16; both, n = 9). Factors associated with VHD by multivariate regression analysis were serum creatinine >2.1 mg/dl (hazard ratio [HR]: 4.143; 95% confidence interval [CI]: 1.740 to 9.866; p = 0.001), porcine tissue valves (HR: 2.241; 95% CI: 1.356 to 3.706; p = 0.002), arterial hypertension (HR: 3.022; 95% CI: 1.424 to 6.410; p = 0.004), and patient-prosthesis mismatch (HR: 1.931; 95% CI: 1.102 to 3.384; p = 0.022). By Kaplan-Meier analysis, elderly subjects showed faster development of VHD (age <70 years, 133.5 months [95% CI: 116.2 to 150.8 months]; 70 to 80 years, 129.1 months [95% CI: 112.4 to 145.7 months]; >80 years, 100.3 months [95% CI: 63.6 to 136.9 months]; p = 0.023). By multivariate Cox regression, age, diabetes, concomitant coronary artery bypass grafting, creatinine, and VHD (p < 0.05) were significantly associated with mortality.

Conclusions: On the basis of echocardiography, every fifth patient developed VHD after surgical bioprosthetic heart valve replacement. VHD was associated with renal impairment, the use of porcine tissue valves, arterial hypertension, and patient-prosthesis mismatch. Patients younger than 70 years were not affected by faster VHD.

Keywords: bioprosthetic aortic valves; echocardiography; risk factors; valve hemodynamic deterioration.

PubMed Disclaimer

Comment in

  • The Unrelenting Search for Bioprosthetic Aortic Valve Durability.
    Alkhouli M. Alkhouli M. JACC Cardiovasc Imaging. 2020 Feb;13(2 Pt 1):354-356. doi: 10.1016/j.jcmg.2019.01.025. Epub 2019 Mar 13. JACC Cardiovasc Imaging. 2020. PMID: 30878416 No abstract available.
  • Is Older Age Truly a Predictor of SVD?
    Vriesendorp MD, de Lind van Wijngaarden RAF, Klautz RJM. Vriesendorp MD, et al. JACC Cardiovasc Imaging. 2019 Nov;12(11 Pt 1):2282. doi: 10.1016/j.jcmg.2019.07.029. JACC Cardiovasc Imaging. 2019. PMID: 31699351 No abstract available.
  • The Authors Reply.
    Nitsche C, Mascherbauer J. Nitsche C, et al. JACC Cardiovasc Imaging. 2019 Nov;12(11 Pt 1):2283. doi: 10.1016/j.jcmg.2019.08.020. JACC Cardiovasc Imaging. 2019. PMID: 31699352 No abstract available.

Publication types

MeSH terms

LinkOut - more resources