Graft Patency after Robotically Assisted Coronary Artery Bypass Surgery

Hiroto Kitahara et al. Innovations (Phila). 2019 Apr.

Abstract

Objective: With advances in robotic instrumentation and technology, both robotically assisted minimally invasive direct coronary artery bypass (RMIDCAB) and totally endoscopic coronary artery bypass (TECAB) have been widely used over the past 20 years. Graft patency is the most important outcome in coronary bypass surgery and is associated with long-term prognosis. In this article we reviewed all experts' studies in the field of robotic assisted coronary artery bypass and investigated graft patency in patients who underwent RMIDCAB or TECAB.

Methods: We performed a literature search in PubMed from 1999 to 2018 using the terms "Robotic" and "Coronary bypass" and/or "Minimally invasive" and/or "Totally endoscopic." Of the articles found, studies investigating graft patency were specifically selected.

Results: In 33 articles, a total of 4,000 patients underwent robotic assisted coronary artery bypass surgery either by a RMIDCAB (2,396) or by a TECAB (1,604) approach. The graft patency was assessed by invasive angiography or computed tomographic angiography in all studies. The mean graft patency at early (<1 month), midterm (<5 years), and long-term (>5 years) follow-up was 97.7%, 96.1%, and 93.2% in RMIDCAB and 98.8%, 95.8%, and 93.6% in TECAB, respectively.

Conclusions: The graft patency of robotic assisted coronary artery bypass was equivalent to reported outcomes of the conventional approach. These results should encourage the adoption of robotic approaches in coronary bypass surgery.

Keywords: graft patency; robotic assisted minimally invasive direct coronary artery bypass; totally endoscopic coronary artery bypass.