Esophageal Heat Exchanger Versus Water-Circulating Cooling Blanket for Targeted Temperature Management
- PMID: 30893023
- DOI: 10.1089/ther.2018.0054
Esophageal Heat Exchanger Versus Water-Circulating Cooling Blanket for Targeted Temperature Management
Abstract
To date, the optimal cooling device for targeted temperature management (TTM) remains unclear. Water-circulating cooling blankets are broadly available and quickly applied but reveal inaccuracy during maintenance and rewarming period. Recently, esophageal heat exchangers (EHEs) have been shown to be easily inserted, revealed effective cooling rates (0.26-1.12°C/h), acceptable deviations from target core temperature (<0.5°C), and rewarming rates between 0.2 and 0.4°C/h. The aim of this study was to compare cooling rates, accuracy during maintenance, and rewarming period as well as side effects of EHEs with water-circulating cooling blankets in a porcine TTM model. Mean core temperature of domestic pigs (n = 16) weighing 83.2 ± 3.6 kg was decreased to a target core temperature of 33°C by either using EHEs or water-circulating cooling blankets. After 8 hours of maintenance, rewarming was started at a goal rate of 0.25°C/h. Mean cooling rates were 1.3 ± 0.1°C/h (EHE) and 3.2 ± 0.5°C/h (blanket, p < 0.0002). Mean difference to target core temperature during maintenance ranged between ±1°C. Mean rewarming rates were 0.21 ± 0.01°C/h (EHE) and 0.22 ± 0.02°C/h (blanket, n.s.). There were no differences with regard to side effects such as brady- or tachycardia, hypo- or hyperkalemia, hypo- or hyperglycemia, hypotension, shivering, or esophageal tissue damage. Target temperature can be achieved faster by water-circulating cooling blankets. EHEs and water-circulating cooling blankets were demonstrated to be reliable and safe cooling devices in a prolonged porcine TTM model with more variability in EHE group.
Keywords: cardiac arrest; cooling; esophagus; induced hypothermia; targeted temperature management.
Similar articles
-
Intravascular Cooling Device Versus Esophageal Heat Exchanger for Mild Therapeutic Hypothermia in an Experimental Setting.Anesth Analg. 2019 Nov;129(5):1224-1231. doi: 10.1213/ANE.0000000000003922. Anesth Analg. 2019. PMID: 30418241
-
Efficacy of different cooling technologies for therapeutic temperature management: A prospective intervention study.Resuscitation. 2018 Mar;124:14-20. doi: 10.1016/j.resuscitation.2017.12.026. Epub 2017 Dec 26. Resuscitation. 2018. PMID: 29288014
-
Oesophageal heat exchangers with a diameter of 11mm or 14.7mm are equally effective and safe for targeted temperature management.PLoS One. 2017 Mar 14;12(3):e0173229. doi: 10.1371/journal.pone.0173229. eCollection 2017. PLoS One. 2017. PMID: 28291783 Free PMC article.
-
Interpreting the results of the targeted temperature management trial in cardiac arrest.Ther Hypothermia Temp Manag. 2015 Jun;5(2):73-6. doi: 10.1089/ther.2014.0031. Epub 2015 Mar 16. Ther Hypothermia Temp Manag. 2015. PMID: 25775183 Review.
-
From therapeutic hypothermia towards targeted temperature management: a decade of evolution.Anaesthesiol Intensive Ther. 2015;47(2):156-61. doi: 10.5603/AIT.a2014.0066. Epub 2014 Nov 25. Anaesthesiol Intensive Ther. 2015. PMID: 25421924 Review.
Cited by
-
Targeted temperature management and early neuro-prognostication after cardiac arrest.J Cereb Blood Flow Metab. 2021 Jun;41(6):1193-1209. doi: 10.1177/0271678X20970059. Epub 2021 Jan 14. J Cereb Blood Flow Metab. 2021. PMID: 33444088 Free PMC article. Review.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Miscellaneous