Aortic dissection following coronary artery bypass surgery: diagnosis by CT
- PMID: 3089621
- DOI: 10.1007/BF02577924
Aortic dissection following coronary artery bypass surgery: diagnosis by CT
Abstract
We describe an unusual case of aortic dissection causing spinal cord infarction. The dissection arose from an intimal tear at the suture line of a coronary artery bypass graft. CT was used to diagnose the dissection and to demonstrate its extension to the aortoiliac bifurcation and innominate artery and its rupture into the left pleural cavity. The most common causes of intimal tears following cardiac bypass surgery are aortic cross-clamping, aortic cannulation, and injury during suturing of the graft to the aorta. An underlying disease of the aorta such as atherosclerosis, cystic medial necrosis, or aortitis is commonly present. CT is an accurate and safe means of detecting aortic dissections following cardiac surgery, and is also useful in assessing the extent of the dissection and identifying its rupture into the pleural or pericardial cavity.
Similar articles
-
Ascending aorta complications of cardiac surgery: CT evaluation.J Comput Assist Tomogr. 1986 Mar-Apr;10(2):219-25. doi: 10.1097/00004728-198603000-00010. J Comput Assist Tomogr. 1986. PMID: 3950149
-
Early Acute Aortic Dissection After Coronary Artery Bypass Grafting.Braz J Cardiovasc Surg. 2025 Feb 12;40(1):e20230342. doi: 10.21470/1678-9741-2023-0342. Braz J Cardiovasc Surg. 2025. PMID: 39937613 Free PMC article.
-
Early type A dissection with the aortic connector device.Eur J Cardiothorac Surg. 2004 May;25(5):902-4. doi: 10.1016/j.ejcts.2004.02.025. Eur J Cardiothorac Surg. 2004. PMID: 15082306
-
Role of transesophageal echocardiography in dissection of the aorta and evaluation of degenerative aortic disease.Cardiol Clin. 1993 Aug;11(3):461-73. Cardiol Clin. 1993. PMID: 8402774 Review.
-
Multidetector CT of Aortic Dissection: A Pictorial Review.Radiographics. 2010 Mar;30(2):445-60. doi: 10.1148/rg.302095104. Radiographics. 2010. PMID: 20228328 Review.
Cited by
-
Aorto-Right Atrial Fistula Caused by Subacute Type A Aortic Dissection Six Months After Double Valve Replacement: A Case Report and Literature Review.Cureus. 2025 Jun 24;17(6):e86692. doi: 10.7759/cureus.86692. eCollection 2025 Jun. Cureus. 2025. PMID: 40718171 Free PMC article.
-
Acute Type A Aortic Dissection Missed as Acute Coronary Syndrome.J Clin Diagn Res. 2016 May;10(5):OD33-4. doi: 10.7860/JCDR/2016/18640.7854. Epub 2016 May 1. J Clin Diagn Res. 2016. PMID: 27437290 Free PMC article.
-
Imaging of aortic abnormalities with contrast-enhanced ultrasound. A pictorial comparison with CT.Eur Radiol. 2007 Nov;17(11):2991-3000. doi: 10.1007/s00330-006-0542-5. Epub 2007 Jan 12. Eur Radiol. 2007. PMID: 17219146
-
A Case of Acute Type A Aortic Dissection after Coronary Artery Bypass Grafting.Ann Thorac Cardiovasc Surg. 2023 Jun 20;29(3):153-156. doi: 10.5761/atcs.cr.21-00193. Epub 2022 Jan 25. Ann Thorac Cardiovasc Surg. 2023. PMID: 35082190 Free PMC article.
-
Incidental Finding of Thoracic Aortic Dissection in a Patient Post-Coronary Artery Bypass Graft Surgery.Cureus. 2023 Jun 15;15(6):e40443. doi: 10.7759/cureus.40443. eCollection 2023 Jun. Cureus. 2023. PMID: 37456414 Free PMC article.
References
Publication types
MeSH terms
LinkOut - more resources
Other Literature Sources
Medical