Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Comparative Study
. 2019 Mar 25;12(6):545-555.
doi: 10.1016/j.jcin.2018.12.014.

Efficacy and Feasibility of the 3-Dimensional Wiring Technique for Chronic Total Occlusion Percutaneous Coronary Intervention: First Report of Outcomes of the 3-Dimensional Wiring Technique

Affiliations
Free article
Comparative Study

Efficacy and Feasibility of the 3-Dimensional Wiring Technique for Chronic Total Occlusion Percutaneous Coronary Intervention: First Report of Outcomes of the 3-Dimensional Wiring Technique

Takamasa Tanaka et al. JACC Cardiovasc Interv. .
Free article

Abstract

Objectives: This study sought to compare the procedural outcomes of percutaneous coronary intervention for chronic total occlusion between the periods before and after introduction of 3-dimensional (3D) wiring.

Background: Previously, we reported a 3D wiring method by which the operator can construct real-time mental 3D images from 2 perpendicular angles of X-ray system monitor during percutaneous coronary intervention for chronic total occlusion.

Methods: A total of 137 chronic total occlusion lesions that could not be passed by tapered soft wires in our hospital between 2012 and 2017 were retrospectively enrolled in the study.

Results: Overall success rate was significantly higher in the 3D wiring group (n = 69) than the non-3D wiring group (n = 68) (98% vs. 90%, respectively; p = 0.027). In the primary antegrade cases, the first antegrade approach time was significantly shorter in the 3D wiring group than the non-3D wiring group (42 ± 29 vs. 30 ± 16 min, respectively; p = 0.01). In cases where the antegrade approach was continued throughout the procedure, the success rate was significantly higher in the 3D wiring group than the non-3D wiring group (100% vs. 89.2%, respectively; p = 0.033). Vessel perforation by the antegrade wire tended to be lower in the 3D wiring group than the non-3D wiring group (1% vs. 11%, respectively; p = 0.055).

Conclusions: 3D wiring enables accurate guidewire control, which improves the success rate of antegrade wiring and reduces the antegrade procedure time, resulting in improvement of the overall success rate.

Keywords: 3-dimensional wiring; coronary occlusion; percutaneous coronary intervention.

PubMed Disclaimer

Comment in

Publication types

MeSH terms

LinkOut - more resources